background image

  

322 Industrial Court, Concord NC, 28025

  

Phone: 704-262-7893

  

Email: [email protected]

  

Web: safewaze.com

 

 Fax: 704-262-9051

I

I

I

I

I

FS-EX311

Standing Seam Roof Anchor

Instruction Manual

OSHA 1926 Subpart M, OSHA 1910, ANSI Z359.1, and ANSI A10.32           

This manual is intended to meet the manufacturer’s instructions as required by 

ANSI Z359 and should be used as part of an employee training program as required 

by OSHA.

WARNING

  

This product is part of a personal fall arrest, work positioning, suspension or rescue system. The 

manufacturer’s instructions must be provided to users of this equipment. The user must follow the 

manufacturer’s instructions for each component of the system. The user must read and understand these 

instructions before using this equipment. Manufacturer’s instructions must be followed for proper use 

and maintenance of this equipment. Alterations to this product, misuse of this product, or failure to follow 

instructions may result in serious injury or death.

IMPORTANT

Questions regarding the use, care, or suitability of this equipment for your application? Contact 

SAFEWAZE™.

IMPORTANT

Record identification information before using this product. Identification information may be found on 

the equipment label. This information should be recorded in the “Inspection Log” located at the back of 

this manual

Do not throw away these instructions!

Read and understand these instructions before using equipment!

User Information

Date of First Use: 

Serial#:

Trainer:

User:

INTRODUCTION

Thank you for purchasing the SAFEWAZE™ FS-EX311 Standiing Seam Roof Anchor.  This manual must 

be read and understood in its entirety, and used as part of an employee training program as required by 

OSHA or any applicable state agency.  This manual and any other instructional material must be 

available to the user of the equipment.  The user must understand how to safely and effectively use the 

FS-EX311, and all fall protection equipment used in conjuction with the anchor.  

APPLICABLE SAFETY STANDARDS

When used according to instructions, the FS-EX311 Standing Seam Roof Anchor meets all applicable 

ANSI Z359.1 standards and OSHA regulations for fall protection.  Applicable standards and regulations 

depend on the type of work being done, and may include state-specific regulations.  Refer to local, state, 

and federal (OSHA) requirements for additional information concerning the governing of occupational 

safety regarding Personal Fall Arrest Systems (PFAS).

WORKER CLASSIFICATIONS

Understand the definitions of those who work in proximity of or may be 

exposed to fall hazards.

Qualified Person:  

“Qualified” means one who, by possession of a recognized degree, certificate, 

or professional standing, or who by extensive knowledge, training, and experience, has successfully 

demonstrated his ability to solve or resolve problems relating to the subject matter, the work, or the 

project.

Competent Person:  

“Competent person” means one who is capable of identifying existing and predict

-

able hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to 

employees, and who has authorization to take prompt corrective measures to eliminate them.

Authorized Person:  

“Authorized person” means a person approved or assigned by the employer to 

perform a specific type of duty or duties or to be at a specific location or locations at the job site.

It is the responsibility of a Qualified or Competent person to supervise the job site and 

ensure safety regulations are complied with.  

PRODUCT SPECIFIC APPLICATIONS

Purpose:  

The SAFEWAZE™ FS-EX311 Standing Seam Roof Anchor is designed to be used as part of 

a Personal Fall Arrest System (PFAS). 

  

- A competent person shall train users on this equipment in accordance with OSHA

 

  and ANSI. 

 

- Never exceed a free fall distance of 6 ft.  A free fall of more than 6 ft could cause 

                            excessive arrest forces that could result in serious injury or death.  

 

- The SAFEWAZE™ FS-EX311 Standing Seam Roof Anchor has a maximum capacity of  

 

  310 lbs including any tools, clothing, accessories, etc..., unless otherwise rated by  

 

  SAFEWAZE™.  

 

- Structures for attachment of SAFEWAZE™ FS-EX311 Standing Seam Roof Anchor  

 

  shall support a minimum 5,000 lbs or be designed with a safety factor of two by a 

 

  Qualified Person.  

 

- All SAFEWAZE™ anchors must IMMEDIATELY be removed from service if subjected  

                            to fall arrest forces.

 

- SAFEWAZE™ anchors shall be inspected by the end user prior to each usage and  

 

  by a Competent Person other than the user every 6 months.  These  inspections shall  

 

  be documented.  

Lanyard Length

(6’ Total)

Deceleration

distance (3.5’ total)

Height of harness dorsal 

D-ring from

worker’s feet

(6’ total) 

Safety factor

(2’ total)

Required

distance

from

Anchorage

(17.5’ total)

Fall Clearance:  

There must be sufficient clearance below the anchorage connector to arrest a fall

before the user strikes the ground or an obstruction.  When calculating fall clearance, account for a

MINIMUM 2’ safety factor, deceleration distance, user height, length of lanyard/SRL, and all other 

applicable factors. (See Figure 1)

LIMITATIONS

Fall Clearance Diagram

***Diagram shown is an example

       fall clearance calculation ONLY.

For all applications: worker weight capacity range

(including all clothing, tools, and equipment) is 130-310 lbs

FIGURE 1 

Swing Falls:  

Prior to installation or use, make considerations for eliminating or minimizing all swing 

fall hazards.  Swing falls occur when the anchor is not directly above the location where a fall occurs. 

Always work as close to in line with the anchor point as possible.  Swing falls significantly increase 

the likelihood of serious injury or death in the even of a fall. (See Figure 2) 

FALLSAFE USA

COMPATIBILITY OF CONNECTORS 

 

Connectors are compatible with connecting elements when they have been designed to work together 

in such a way that their sizes and shapes do not cause their gate mechanisms to inadvertently open 

regardless of how they become oriented.  Connectors (hooks, carabiners, and D-rings) must be 

capable of supporting at least 5,000 lbs. (22.2 kN). Connectors must be compatible with the anchorage 

or other system components (see Figure 4). 

Do not use equipment that is not compatible

. Non-

compatible connectors may unintentionally disengage (see Figure 3). Connectors must be compatible 

in size, shape, and strength. Self-locking snap hooks and carabiners are required by ANSI Z359 and 

OSHA guidelines.  Contact SAFEWAZE™ if you have any questions about compatibility

.

FIGURE 3 - UNINTENTIONAL DISENGAGEMENT

3 - Gate opens

2 - Gate presses 

against 

non-compliant 

part

4 - And parts 

disengage.

1 - Non Compliant Part

 

NOTE:

 SOME SPECIALITY CONNECTORS HAVE ADDITIONAL 

REQUIREMENTS.  CONTACT SAFEWAZE™ WITH QUESTIONS.

FIGURE 2

FIGURE 4 - INAPPROPRIATE CONNECTIONS

MAKING CONNECTIONS

  

Snap hooks and carabiners used with this equipment must be double locking and/or twist lock.  Ensure 

all connections are compatible in size, shape and strength. Do not use equipment that is not compatible. 

Ensure all connectors are fully closed and locked.

SAFEWAZE™ connectors (snap hooks and carabiners) are designed to be used only as specified 

in each product’s user’s instructions. See figure 4

 

for examples of inappropriate connections. Do not 

connect snap hooks and carabiners:

•  To a D-ring to which another connector is attached. 

• 

In a manner that would result in a load on the gate (with the exception of tie back hooks). NOTE: 

Large snap hooks must not be connected to objects which will result in a load on the gate if the hook 

twists or rotates. Snap hooks marked with ANSI Z359.12 and are equipped with a 3,600 lb (16 kN) 

gate. Check the marking on your snap hook to verify its compatibility. 

NOTE:

 Large throat snap hooks must not be connected to standard size D-rings or similar 

objects which will result in a load on the gate if the hook or D-ring twists or rotates, unless 

the snap hook complies with ANSI Z359.1-2007 or ANSI Z359.12 and is equipped with a 

3,600 lb (16 kN) gate. Check the marking on your snap hook to verify that it is appropriate 

for your application.

• 

In a false engagement, where features that protrude from the snap hook or carabiner catch on the 

anchor, and  without visual confirmation seems to be fully engaged to the anchor point. 

•  To each other. 

•  By wrapping the web lifeline around an anchor and securing to lifeline except as allowed for Tie Back 

models.

• 

To any object which is shaped or sized in a way that the snap hook or carabiner will not close and 

lock, or that  roll-out could occur. 

• 

In a manner that does not allow the connector to align properly while under load. 

Using a connector that is undersized or irregular in shape (1) to connect a snap hook or carabiner could 

allow the connector to force open the gate of the snap hook or carabiner. When force is applied, the gate 

of the hook or carabiner presses against the non-compliant part (2) and forces open the gate (3). This 

allows the snap hook or carabiner to disengage (4) from the connection point. 

2037

SPECIFIC ANCHOR APPLICATIONS

Personal Fall Arrest: 

The FS-EX311 Standing Seam Roof Anchor is 

designed as an anchor point to support a maximum of 1 Personal Fall 

Arrest System (PFAS) when utilized for fall protection applications. The 

structure to which the anchor is attached must withstand loads applied in 

the directions permitted by the system of at least 5,000 lbs.  Maximum 

allowable free fall is 6’.  

Restraint: 

The FS-EX311 Standing Seam Roof Anchor is authorized 

for use in Restraint applications. The structure to which the anchor is 

attached must withstand loads applied in the directions permitted by the 

system of at least 1,000 lbs. NO free fall is permitted. Restraint systems 

may only be used on surfaces with slopes up to 4/12 (vertical / horizontal).  

For Restraint applications, the allowable attachment points to harness are 

Dorsal D-ring, Chest D-ring, Side D-rings, and Shoulder D-rings.   

Work Positioning: 

The FS-EX311 Standing Seam Roof Anchor is 

authorized for use in Work Positioning applications.  Work Positioning 

allows a worker to be supported during suspension while freeing both 

hands to conduct work operations.  The structure to which the Chain 

Anchor is attached must withstand loads applied in the directions 

permitted by the system of at least 3,000 lbs.  Maximum allowable free 

fall is 2’.  For positioning applications, the allowable attachment points to 

harness are the Side D-rings.  

Rescue/Confined Space: 

The FS-EX311 Standing Seam Roof Anchor 

is authorized for use in Rescue/Confined Space applications. Rescue 

systems are utilized to safely recover a worker from a confined location or 

after exposure to a fall.  Composition of rescue systems can vary based 

upon the type of rescue involved.  The structure to which a Chain Anchor 

is attached must withstand loads applied in the directions permitted by the 

system of at least 3,000 lbs.  NO free fall is permitted.  For rescue 

applications, the allowable attachment points to harness are Dorsal 

D-ring, Chest D-ring and Shoulder D-rings.   

All above referenced applications have a worker weight capacity range of 310 lbs 

(including all clothing, tools, and equipment).

Reviews: