background image

2023 Copyright Safewaze

5

Snap hooks and carabiners used with this equipment must be double locking and/or twist lock. Ensure all connections 

are compatible in size, shape and strength. Do not use equipment that is not compatible. Ensure all connectors are fully 

closed and locked.

Safewaze connectors (snap hooks and carabiners) are designed to be used only as specified in each product’s user 

instructions. See Figure 4 for examples of inappropriate connections. Do not connect snap hooks and carabiners:

•  To a D-ring to which another connector is attached. 

•  In a manner that would result in a load on the gate (with the exception of tie-back hooks). NOTE: Large snap hooks 

must not be connected to objects which will result in a load on the gate if the hook twists or rotates, unless the snap 

hook complies with ANSI Z359.12 and is equipped with a 3,600 lbs. (16 kN) gate. Check the marking on your snap 

hook to verify its compatibility. 

 13.0  MAKING CONNECTIONS

FIGURE 4 - INAPPROPRIATE CONNECTIONS

 14.0  SPECIFIC ANCHOR APPLICATIONS

Personal Fall Arrest:

  

Safewaze Anchors are designed as an anchor point to support a maximum 

of 1 Personal Fall Arrest System (PFAS) when utilized for fall protection applications.  The structure 

to which the anchor is attached must withstand loads applied in the directions permitted by the  

system of at least 5,000 lbs.  Maximum allowable free fall is 6’.  

Restraint: 

Safewaze Anchors are authorized for use in Restraint applications. The structure to 

which the anchor is attached must withstand loads applied in the directions permitted by the system 

of at least 1,000 lbs   NO free fall is permitted. Restraint systems may only be used on surfaces 

with slopes up to 4 / 12 (vertical / horizontal).  For Restraint applications, the allowable attachment 

points to harness are Dorsal D-ring, Chest D-ring, Side D-rings, and Shoulder D-rings.   

Work Positioning: 

Safewaze Anchors are authorized for use in Work Positioning applications.  

Work Positioning allows a worker to be supported during suspension while freeing both hands to 

conduct work operations.  The structure to which the Anchor is attached must withstand loads  

applied in the directions permitted by the system of at least 3,000 lbs.  Maximum allowable free fall 

is 2’.  For positioning applications, the allowable attachment points to harness are the Side D-rings.  

Rescue/Confined Space:

 

Safewaze Anchors are authorized for use in Rescue/Confined Space 

 

applications. Rescue systems are utilized to safely recover a worker from a confined location or 

after exposure to a fall.  Composition of rescue systems can vary based upon the type of rescue 

involved.  The structure to which the Anchor is attached must withstand loads applied in the  

directions permitted by the system of at least 3,000 lbs.  NO free fall is permitted.  For rescue  

applications, the allowable attachment points to harness are Dorsal D-ring, Chest D-ring and  

Shoulder D-rings.   

All above referenced applications have a worker weight capacity range of: 

ANSI 310 lbs. / OSHA Up to 420 lbs. (including all clothing, tools, and equipment).

Summary of Contents for 021-4068

Page 1: ...First Use ______________________________ Serial ____________________________________ Trainer ____________________________________ User ______________________________________ Sliding Beam Anchors Inst...

Page 2: ...NCY 4 10 0 RESCUE PLAN 4 11 0 COMPATIBILITY OF COMPONENTS 4 12 0 COMPATIBILITY OF CONNECTORS 4 13 0 MAKING CONNECTIONS 5 14 0 SPECIFIC ANCHOR APPLICATIONS 5 15 0 ANCHOR COMPONENTS 6 16 0 INSTALLATION...

Page 3: ...Some subsystem components could affect the performance and the operation of this equipment Do not anchor this product to moving machinery or hazards that have chemical electrical or gaseous character...

Page 4: ...tion criteria for the equipment shall be set by the user s organization Such criteria for the equipment shall equal or exceed the criteria established by this standard or the manufacturer s instructio...

Page 5: ...ls trained in its proper application Fall Clearance There must be sufficient clearance below the anchorage connector to arrest a fall before the user strikes the ground or an obstruction When calculat...

Page 6: ...or LA Length of Connecting device LC Maximum Arrest Distance of connecting device MAD Height of Worker HW Safety Factor SF Includes harness stretch typically 2 Distance from Anchor Point to next close...

Page 7: ...a safety factor of two by a Qualified Person All Safewaze full body harnesses must IMMEDIATELY be removed from service if subjected to fall arrest forces Safewaze full body harnesses shall be inspecte...

Page 8: ...sustaining static loads applied in the directions permitted by the system of at least 1 5 000 lbs 22 2 kN for non certified anchorages or 2 Two times the maximum arresting force for certified anchorag...

Page 9: ...in Restraint applications The structure to which the anchor is attached must withstand loads applied in the directions permitted by the system of at least 1 000 lbs NO free fall is permitted Restrain...

Page 10: ...021 4075 Anchor Components Material A Clamp Assembly Aluminum Alloy B Adjustment Lever Aluminum Steel C Fall Protection Attachment Point Plated Steel D Support Bar Aluminum Alloy E Composite Rollers N...

Page 11: ...mation of any component improper function of the adjustment levers fall protection connection point damaged or missing chemical or excessive heat exposure are present the anchor MUST BE REMOVED FROM S...

Page 12: ...maged or missing chemical or excessive heat exposure are present the anchor MUST BE REMOVED FROM SERVICE 5 After inspection of the installation location adjust the Beam Anchor in to fit the beam dimen...

Page 13: ...ected to fall arrest forces or inspection reveals an unsafe or defective condition If unsafe or defective condition is found dispose of the anchor as recommended in section 21 0 19 0 MAINTENANCE CLEAN...

Page 14: ...ll arrest forces or inspection reveals an unsafe or defective condition Before disposing of the anchor ensure it is marked as damaged and unsafe for use 23 0 PRODUCT LIFE 24 0 DISPOSAL MUST FOLLOW ALL...

Page 15: ...eterioration Corrosion Cuts Burns Holes Integrity of Welds Rivets Paint Contamination Stitching Wire Condition Heat Corrosion UV Damage Separation Bird Caging PASS PASS PASS FAIL FAIL FAIL NOTE NOTE N...

Page 16: ...2023 Copyright Safewaze Safewaze 225 Wilshire Ave SW Concord NC 28025 PHONE 1 800 230 0319 FAX 1 704 262 9051 WEB Safewaze com EMAIL info Safewaze com...