background image

2023 Copyright Safewaze

11

Product lifetime is indefinite as long as it passes pre-use and Competent Person inspections.  User must inspect prior to 

each use.  Competent Person other than the user must complete formal inspection at least annually.

If equipment fails inspection 

IMMEDIATELY REMOVE FROM SERVICE

Label

Label (Intact and Legible)

Appropriate ANSI / OSHA / CSA Markings

Inspections are Current / Up-to-Date

Date of First Use

Signs of Deformity

D-Ring / Connection Points

Hook Gate / Rivets (if applicable)

Corrosion / Pitting / Nicks

Termination (Stitch, Splice, or Swage)

Deterioration / Corrosion

Cuts / Burns / Holes

Integrity of Welds / Rivets

Paint Contamination

Stitching / Wire Condition

Heat Corrosion / UV Damage

Separation / Bird-Caging

PASS

PASS

PASS

FAIL

FAIL

FAIL

NOTE

NOTE

NOTE

LABELS & MARKINGS

HARDWARE

 

(If Applicable)

ANCHORAGE CONNECTOR

    
    

Connection  

Point

Termination

Label

Webbing

Cable

POST ANCHOR

ROOF ANCHOR

Connection  

Point

Welds & 

Rivets

Labels

CABLE ANCHOR

CROSS ARM STRAP

INSPECTION FORM

ANCHORS

Model Number: 

 

Name of Inspector:

  

Serial Number:  

Description: 

 

Signature:  

Lot Number: 

 

Date of Inspection: 

 

Date of Manufacture:  

Anchor  
Material:

  

In-Service Date:

  

Company:

  

Manufacturer:  

Galvanized Steel

Zinc-Plated Steel

Stainless Steel

Aluminum

Other:

 

NOTES

225 Wilshire Avenue SW, Concord NC 28025 

• 

800-230-0319 

• 

www.safewaze.com

 26.0  INSPECTION FORM 

Summary of Contents for 021-4068

Page 1: ...First Use ______________________________ Serial ____________________________________ Trainer ____________________________________ User ______________________________________ Sliding Beam Anchors Inst...

Page 2: ...NCY 4 10 0 RESCUE PLAN 4 11 0 COMPATIBILITY OF COMPONENTS 4 12 0 COMPATIBILITY OF CONNECTORS 4 13 0 MAKING CONNECTIONS 5 14 0 SPECIFIC ANCHOR APPLICATIONS 5 15 0 ANCHOR COMPONENTS 6 16 0 INSTALLATION...

Page 3: ...Some subsystem components could affect the performance and the operation of this equipment Do not anchor this product to moving machinery or hazards that have chemical electrical or gaseous character...

Page 4: ...tion criteria for the equipment shall be set by the user s organization Such criteria for the equipment shall equal or exceed the criteria established by this standard or the manufacturer s instructio...

Page 5: ...ls trained in its proper application Fall Clearance There must be sufficient clearance below the anchorage connector to arrest a fall before the user strikes the ground or an obstruction When calculat...

Page 6: ...or LA Length of Connecting device LC Maximum Arrest Distance of connecting device MAD Height of Worker HW Safety Factor SF Includes harness stretch typically 2 Distance from Anchor Point to next close...

Page 7: ...a safety factor of two by a Qualified Person All Safewaze full body harnesses must IMMEDIATELY be removed from service if subjected to fall arrest forces Safewaze full body harnesses shall be inspecte...

Page 8: ...sustaining static loads applied in the directions permitted by the system of at least 1 5 000 lbs 22 2 kN for non certified anchorages or 2 Two times the maximum arresting force for certified anchorag...

Page 9: ...in Restraint applications The structure to which the anchor is attached must withstand loads applied in the directions permitted by the system of at least 1 000 lbs NO free fall is permitted Restrain...

Page 10: ...021 4075 Anchor Components Material A Clamp Assembly Aluminum Alloy B Adjustment Lever Aluminum Steel C Fall Protection Attachment Point Plated Steel D Support Bar Aluminum Alloy E Composite Rollers N...

Page 11: ...mation of any component improper function of the adjustment levers fall protection connection point damaged or missing chemical or excessive heat exposure are present the anchor MUST BE REMOVED FROM S...

Page 12: ...maged or missing chemical or excessive heat exposure are present the anchor MUST BE REMOVED FROM SERVICE 5 After inspection of the installation location adjust the Beam Anchor in to fit the beam dimen...

Page 13: ...ected to fall arrest forces or inspection reveals an unsafe or defective condition If unsafe or defective condition is found dispose of the anchor as recommended in section 21 0 19 0 MAINTENANCE CLEAN...

Page 14: ...ll arrest forces or inspection reveals an unsafe or defective condition Before disposing of the anchor ensure it is marked as damaged and unsafe for use 23 0 PRODUCT LIFE 24 0 DISPOSAL MUST FOLLOW ALL...

Page 15: ...eterioration Corrosion Cuts Burns Holes Integrity of Welds Rivets Paint Contamination Stitching Wire Condition Heat Corrosion UV Damage Separation Bird Caging PASS PASS PASS FAIL FAIL FAIL NOTE NOTE N...

Page 16: ...2023 Copyright Safewaze Safewaze 225 Wilshire Ave SW Concord NC 28025 PHONE 1 800 230 0319 FAX 1 704 262 9051 WEB Safewaze com EMAIL info Safewaze com...

Reviews: