Reference manual

 

 

 

Summary of Contents for MegaGuard Pro

Page 1: ...SG9265051 Reference manual ...

Page 2: ...ator s security avoid to touch the electrodes directly WARRANTY This unit is guaranteed against all defects due to faulty materials and workmanship within 12 months from the date of purchase A use not conforming to what specified might be dangerous to the safety of the operator and may damage the instrument In such circumstances the manufacturer is relieved of any liability and the warranty itself...

Page 3: ... digit Accuracy decade Graphic liquid crystal display 102x64 pixel 34x23mm Measuring voltage 10Vdc for R 100kΩ 100Vdc for R 100kΩ Dimensions 80x120x27mm Weight 200g Battery 9 V LOW BATTERY Blinking Auto Shut off after 5 minutes of inoperativity PROBES AND ACCESSORIES SG9265065 Shielded probe made to IEC 61340 5 1 63 30mm diameter 2 5Kg weight optional SG9265070 Concentric ring PROBE made to IEC 61...

Page 4: ...alibration certificate Box Kit SG9265056 includes 1 MegaGuard Pro with battery 2 connection cables SG9265013B 3 5mm jack banana4mm 2 probes SG9265065 Manual ISO9000 traceable calibration certificate Carrying case PANEL LEFT SOCKET Input for external probe RIGHT SOCKET Input for external probe MEASURING VOLTAGE BATTERY LEVEL MEASUREMENT BUTTON BATTERY COVER ...

Page 5: ...x1009 Ω Natural format 4GΩ In the lower part of the display the measurement voltage is indicated 10V or 100V KEYBOARD Button 10x To display the measured resistance in natural or exponential format To enter the programming mode To move to the next menu while in programming mode Button MEASURE To make the measurement To increase the value at the cursor location when you are in programming mode Key E...

Page 6: ...d to the 3 5mm jack Left Socket and Left Measuring Rubber In one of these two points the SIGNAL measurement input is present The SIGNAL measurement input is connected to the Left Measuring Rubber When the 3 5mm jack is inserted into the Left Socket the Left Measuring Rubber is automatically disconnected and the SIGNAL measurement input connected to the 3 5mm jack EXTERNAL PROBE CONNECTION SG926506...

Page 7: ...e an isolant layer In case of doubt clean the surface with a specifical detergent without alcohol or silicon so that the non conductive layer will be removed Insert the 3 5mm jack of the connecting cable into the Left Socket SIGNAL measurement input and connect the banana 4mm to a safe ground point Place meter on test surface Press the central MEASURE button and keep it pressed by applying a press...

Page 8: ...tors under a c voltage problems on the readings may occur because 50Hz may cause an interference with the LABEOHM measuring circuit especially when measuring high resistance values In case of doubt disconnect the mains power supply by opening the main switch ALARM PROGRAM In program mode you can set an audible alarm sounds when the resistance measurement is below or above a certain threshold Hold ...