MAX100/200-OPERATION Rev200813
26
Accessing Water Flow Simulation Mode
Press the blue SELECT button several times until "
Simulated Water Flow
" is displayed on selectable display at
the bottom of the screen. The value on the display will read "
OFF
". To activate water flow simulation, press and hold the
yellow
UP/DOWN
buttons simultaneously. When activated, this value will change to a number and start to flash. The
number shown on the display is the simulated water flow rate for –this discharge.
"
Simulated Water Flow
" can be adjusted by using the yellow
UP/DOWN
buttons. To change the foam proportioning
rate during water simulation mode, press the blue
SELECT
button once. The water flow rate will stop flashing and the
foam proportioning rate setting will start to flash. Adjust the foam proportioning rate in the normal manner by using the
yellow
UP/DOWN
buttons.
Press the blue SELECT button at any time to switch between "
Simulated Water Flow
" and "
Foam Proportioning
Rate
" to make adjustments to them.
To Cancel "
Simulated Water Flow
" mode,
press and hold the UP/DOWN buttons simultaneously
until the
value is turned "OFF" on the display.
• When operating the FoamPro AccuMax System in the “Simulated Mode” function, an outlet for the foam concentrate
must be provided. Otherwise, dangerous excessive pressure may build up in the apparatus water piping and/or hoses.
This outlet for the foam concentrate can be provided by turning the “CAL/INJECT” valve to the “CAL” position. A
suitable container must be provided to collect the foam concentrate.