MAX100/200-OPERATION Rev200813
17
7. OPERATION OF SYSTEM
Screen Overview
On power-up the display module will be in the normal operating mode. The red ON/OFF button, yellow decrease (-)/
increase (+) buttons and blue
SELECT
button are used to control the foam system operation.
For the MAX200 Fusion
model, the green
OPEN
, red
CLOSE
, and yellow
PRESET
buttons will control the water valve position. The yellow
PRESET
button will set the valve to a programmed position. The blue
MENU
button switches to the Menu Screen.
(
Menu Screen is activated when this button is pressed and held down for two seconds.
)
Foam system state and operating parameters will be shown on the display screen along with system messages,
warnings and error codes.
Operator Screen
The operator screen loads upon the initial start-up. All information needed to operate the system is shown on this screen.
• Foam on/off indicator
• Foam class indicator
• Foam proportioning rate (%)
• Fixed operational parameter shown at the top of the screen
• Toggle through Parameter display (changeable with select button)
• Foam tank level indicator (if equipped), system messages
• Warnings and error/fault messages
•
User-assigned identification: name and color codes.
• NOTE: MAX200 Fusion models feature a valve position.
Button Operations
• Red
ON/OFF
button: Press and hold for 2 seconds to start/stop the foam proportioning.
• Yellow Decrease button (-): Press to switch to the foam percentage to a lower preset. Press and hold to make a temporary
adjustment to the foam percentage in 0.1% increments.
• Yellow Increase button (-): Press to switch to the foam percentage to a higher preset. Press and hold to make a temporary
adjustment to the foam percentage in 0.1% increments.
For MAX200 Fusion only:
• Green
OPEN
button: Press and hold to drive a valve toward the Open position. Valve will stop when the button is
released, or when it is fully open.
• Red
CLOSE
button: Press and hold to drive a valve toward the Closed position. Valve will stop when the button is
released, or when it is fully closed.
• Yellow
PRESET
button: Press and hold once; upon release the valve will travel to a preprogrammed position and stop
there. Press and hold
PRESET
button for three seconds to save the current valve position as a preset position. This will
be saved into the valve actuator's internal memory.