INTEGRA-W/INTEGRA-WS User Manual WEB GUI
SAF Tehnika JSC
38
1)
Indicates low, high and delta values of the parameters (status mode); “Low value”,
“High value” and “Delta value” fields for all parameters become editable when
“Default value” is deselected (modify mode);
2)
Set all to default
– resets “Low value”, “High value” and “Delta value” for all
parameters to factory defaults;
3)
Default value
– deselect to activate manual threshold modification;
4)
By pressing
„Execute configuration”
changes made to the corresponding section
apply only for the local side Integra-W/Integra-WS.
CLI commands (
log sensor info
Use to show configuration of sensor thresholds.
log sensor mgmt
<sensor>
control
<auto|user>
Use to set sensor thresholds to user defined or automatically
adjusted.
log sensor mgmt
<sensor>
thold
<min> <max> <delta>
Use to set sensor’s min, max thresholds and delta value
manually.
log sensor mgmt
<sensor>
time
<0…30>
Use to set sensor hysteresis time in seconds. Will be used to
show value in orange colour indicating that sensor value
recently exceeded its thresholds.
log default
<all|group|sensors>
Use to set group, individual sensor or all sensor configuration
to default.
log sensor list
Use to list all available sensors.
Performance
Monitoring
Performance graph
Performance graph allows visualising various parameters over chosen time period as
curves. Available parameters will depend on
. Any two parameters can
be shown at a time. By default Rx level (dBm) and Radial MSE (dB) are selected.
Not all sensors available in
can be displayed in Performance
graph.
MODIFY button is deactivated in Performance graph page.