INTEGRA-W/INTEGRA-WS User Manual INSTALLATION
SAF Tehnika JSC
17
Connecting Integra-W/Integra-WS FODU FO
interface using fiber conduit kit
1
Fiber conduit kit.
2
Unscrew the cap of the SFP port (LAN2 or LAN3) that
will be used and install a SFP module.
3
Disassemble conduit kit and put its parts in
the following sequence (left – Integra-W
direction, right – CPE direction)
.
4
Push FO cable from LC connector side through the
conduit.
5
Connect LC connector to SFP module
.
6
Tighten parts on both ends of the conduit. Fasten
other end of fiber conduit to the pole using included
tie-wrap. Assembled view.