41
The TRAUS SSG10 is intended for use in the electromagnetic environment specified below. The customer or the user of the TRAUS SSG10
should assure that is used in such an environment.
Note 1:
At 80 MHz and 800 MHz, the higher frequency range applies.
Note 2:
These specifications may not be applicable in all situations. Electromagnetic propagation is affected by absorption and reflection
from structures, objects and persons.
(a): The electromagnetic field strength of fixed radiofrequency emitters, such as base stations for mobile telephones (cellular / cordless),
mobile radio, AM/FM radio broadcasts and TV broadcasts cannot be determined exactly by theory. To assess the electromagnetic
environment due to fixed radiofrequency emitters, an electromagnetic environment measurement must be made. If the measured
radiofrequency field strength in the immediate environment where the product is used exceeds the compliance level specified above,
the performance of the product must be tested to verify whether it conforms to the specification. If abnormal performance is observed,
additional measures may be necessary, such as reorienting or relocating the product.
(b): In the 150 kHz to 80 MHz frequency range, the electromagnetic field strengths must be less than 3V/m.
Compliance level
Electromagnetic environment – guidance
Immunity test
IEC 60601 test level
Electromagnetic Immunity
Conducted RF
IEC 61000-4-6
EN 61000-4-6
Radiated RF
IEC 61000-4-3
EN 61000-4-3
3 Vrms
150kHz to 80MHz
3 V/m
80MHz to 2.5GHz
3 V/m
3Vrms
Portable and mobile RF communications
equipment should be used no closer to
any part of the TRAUS SSG10 including
cables, than the recommended separation
distance calculated from the equation
applicable to the frequency of the
transmitter.
Recommended separation distance
d = 1.2 √P
d = 1.2 √P 80MHz to 800MHz
d = 2.3 √P 800MHz to 2.5GHz
Where ‘P’ is the maximum output power
rating of the transmitter in watt (W) according
to the transmitter manufacturer
‘d’ is the recommended separation distance (m).
The electromagnetic field strength of fixed
radiofrequency emitters, which is determined
by an electromagnetic environment
measurement (a), must be less than the
compliance level in each frequency range (b).
Interference may occur near equipment
marked with the symbol below:
For transmitters rated at a maximum output power not listed above, the recommended separation distance ‘d’ in meters (m)
can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power
rating of the transmitter in watts (W) according to the transmitter manufacturer.
Note 1:
At 80 MHz and 800 MHz, the higher frequency range applies.
Note 2:
These specifications may not be applicable in all situations. Electromagnetic propagation is affected by absorption
and reflection from structures, objects and persons.
Recommended separation distances between portable and mobile RF communications equipment and the TRAUS SSG10
Separation distance according to frequency of transmitter (m)
Rated maximum output
Power of transmitter
(W)
The TRAUS SSG10 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
The customer or the user of the TRAUS SSG10 can help prevent electromagnetic interference by maintaining a minimum
distance between portable and mobile RF communications equipment (transmitters) and the TRAUS SSG10 as recommended
below, according to the maximum output power of the communications equipment
0.01
0.1
1
10
100
0.12
0.38
1.2
3.8
12
0.12
0.38
1.2
3.8
12
0.23
0.73
2.3
7.3
23
150 kHz ~ 80 MHz
d = 1.2 √P
80 MHz ~ 800 MHz
d = 1.2 √P
800 MHz ~ 2.5 GHz
d = 2.3 √P
Summary of Contents for TRAUS SSG10
Page 1: ...www saeshin com USER MANUAL SSG10...
Page 2: ...SSG10...
Page 6: ...AC 100 120V 220 240V 3...
Page 8: ...LCD EMC EMC Electromagnetic Compatibility ISO 1797 1 1 2 3 4 1 2 3 4 5...
Page 14: ...SETUP SETUP SETUP 1 2 11 LCD...
Page 20: ...1 1 1 1 2 2 1 1 2 3 1 1 0 4 3 2 1 4 2 3 5 1 4 17...
Page 22: ...1 2 3 O X 19 4 A B C B 1 D C 1...
Page 26: ...23 DRILL SAW SHAVER 8 9 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3...
Page 36: ...33 M1 M2 M1 M2 1 10 20 3 10 3 3 70 30 2 1...
Page 42: ...IEC 60529 TRAUS FUS10 IPX8 6 39 1 1 2 SETUP SETUP SETUP EU CE BF 1639 NON STERILE...
Page 46: ...43 MEMO...
Page 47: ...44 MEMO...