USER GUIDELINES
CAUTION
• Please pay attention to the use considering the patient’s safety first of all.
• Check condition of the product before use.
• Stop to use and inspect the product when an abnormal sign such as calescence, vibration or noise
occurs before or during operation.
• Please contact manufacturer if cannot find reason of problem, or cannot solve the problem.
• Replace the bur or file after the motor is completely stopped. Otherwise, inside of the angle
could be damaged, and it could cause an accident.
• Please sterilize and lubricate the handpiece right after use. Otherwise, the product could be
damaged due to coagulation of blood inside the product.
• This product is not sterilized when shipped from the manufacturer.
Refer to the maintenance section of the product and sterilize components that require sterilization
before use.
• The control box, motor, foot controller and adaptor are not steam sterilization objects.
• Contact manufacturer if incorrect display is on the screen. There is a risk of an accident.
• Do not drop or give a strong impact to the product. It may cause a breakdown.
• Do not insert oil into the motor. It will damage bearing or cause calescence.
• The product is designed to be used indoor, do not use outdoor.
• Do not use the product in humid or dusty environment.
• Use the regulated products and consumables by manufacturer. Otherwise there might be a risk of
an accident or failure.
• User has responsibility to operate and maintain the product.
• This product uses a rechargeable battery [Ni-MH battery]. Recycling is possible, but some countries
may not allow processing, so return it to the place of purchase.
• When connecting the cord and connector, check the direction and attach it.
• When the battery bar is one level on the screen, please charge it as much as possible.
• If the battery has been almost discharged, the battery level on the screen is blank and a beep sounds.
Stop using it immediately and charge it..
• When using apex measurements, check if the patient is allergic to metals.
• Excessive force on the root canal may result in damage or blockage of the root canal wall caused by the file.
• Be careful when using reverse rotation, as the torque of the motor is strong and the file may be broken.
WARNING
• Please watch old person, children, or disabled person near the place that the product is installed.
If so, do not let them alone.
• Portable and mobile radio frequency communications equipment may affect the product.
Do not use radio frequency equipment in close proximity for the product.
• Before measuring root canal length, make sure the "Auto Start/Stop" function is turned off.
If it is on, the motor will rotate automatically.
• If the root canal is blocked or under special circumstances, the measurement may not be
possible or accurate.
• Do not let the metal part of the contra-angle come into contact with the oral mucosa.
There is a risk of an accident due to the rotation of the motor.
• Do not modify this equipment without authorization of the manufacturer.