EN
If the blade does not slot into the machine or the mechanism does not open
enough to remove a blade then the below steps can be followed to resolve:
1. Unscrew the bolt on the right side with a Philips screwdriver
2. Use a flat screwdriver and turn and then lift bolt up to remove it and
place to the side
3. Remove the metal lever from shell and place to the side
4. Turn the black bolt Clockwise/Anticlockwise to decrease/increase the
gap in the mechanism.
5. Perform the steps in reverse to re-attach the lever
Summary of Contents for Extreme SCMTK400/EU