background image

MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE

INSTALLATION, USE AND MAINTENANCE MANUAL

MANUEL D’INSTALLATION, D’UTILISATION ET D’ENTRETIEN

10/2022

Cod. 4050329

COMANDO A PARETE

 WALL CONTROL

COMMANDE MURALE

9066994E

9066994E

T-MB2

T-MB2

Summary of Contents for T-MB2

Page 1: ...ALLAZIONE USO E MANUTENZIONE INSTALLATION USE AND MAINTENANCE MANUAL MANUEL D INSTALLATION D UTILISATION ET D ENTRETIEN 10 2022 Cod 4050329 COMANDO A PARETE WALL CONTROL COMMANDE MURALE 9066994E 90669...

Page 2: ...23 5 lun 08 00 25 0 115 mm 75 mm 20 5 mm h 150cm 23 5 lun 08 00 25 0 23 5 lun 08 00 25 0 23 5 lun 08 00 25 0 50 cm min 23 5 lun 08 00 25 0 1 7 D 12V 6 D 5 GND 2 3 3a 4 5...

Page 3: ...della numera zione comune ad entrambe le schede Utilizzare 3 conduttori con sezione 0 5 mm2 NOTA La lunghezza del cavo di collegamento non deve essere superiore ai 20 metri COLLEGAMENTI ELETTRICI DEL...

Page 4: ...t MEDIA FAN 3 gradini Mode Automatico Men Installatore Velocit MASSIMA FAN 3 gradini Mode Ventilazione Informazioni Velocit AUTOMATICA Men attivazione Flap Swing Segnalazione Swing Attivo Diagnostica...

Page 5: ...elle funzioni utilizzare i tasti Ad ogni pressione avviene uno spostamento Conferma per confermare la scelta del men o della funzione utilizzare il tasto PANORAMICA DEI MENU Mode AUTO Mode Estate Raff...

Page 6: ...A PRIMARIE ON OFF 23 5 08 30 25 0 Impostazione MODE M Lun Impostazione SET 18 5 lun 08 30 19 0 18 5 lun 08 30 21 0 Impostazione VELOCITA 23 5 lun 08 00 25 0 1 3 4 5 6 7 8 9 10 A 2 AUTO MIN MED MAX FAN...

Page 7: ...gramma TIMER precedentemente configurato attivare seguire la istru zione sotto riportata NOTA il programma TIMER APP fa riferimento alla configurazione che stata generata attraverso l applicazione Sab...

Page 8: ...LED GIOVED VENERD SABATO DOMENICA IMPORTANTE Prima di modificare o eliminare un programma TIMER occorre che sia atti vato nel men Attivazione vedi capitolo dedicato TIMER Modifica Programma 07 00 22 0...

Page 9: ...MERCOLED GIOVED VENERD SABATO DOMENICA LUNED MARTED MERCOLED GIOVED VENERD SABATO DOMENICA LUNED MARTED MERCOLED GIOVED VENERD SABATO DOMENICA FUNZIONALITA SECONDARIE 23 5 lun 08 30 25 0 ON OFF ON OF...

Page 10: ...ciclo di antistratificazione Ciclo Power On Stato contatto finestra Stato on off remoto Allarme pompa se disponibile ALLARMI Versione MB AL1 sonda T1 guasta AL2 sonda T2 guasta AL3 sonda T3 guasta AL4...

Page 11: ...morta 18 30 C dEdr Campo di impostazione zona morta 1 6 C BMS Modalit sotto supervisione On Off ON OFF dS dS Range di variazione del set con T MB 9 C 3 C 9 C T2 1 Cambio stato da ventilazione a raffre...

Page 12: ...ettimanale impostando per ciascun giorno della settimana fino a quattro diversi livelli di lavoro Per poter utilizzare l applicazione sufficiente dispor re di una connessione WiFi e scaricare la nostr...

Page 13: ...anufacturer and reported within the manufacturer s documentation The control accordance with the relating safety Standards and Directives is assured only and exclusively according to such combinations...

Page 14: ...speed Flap Swing activation menu Active Swing signaling Troubleshooting Status view LINEAR speed 1 10 Volt range if available IAQ activation menu Active IAQ Filter signaling Alarm presence Stand by Ni...

Page 15: ...erating mode press the buttons At each pressure a shifting takes place To Confirm to confirm the choice of the menu or of the opera ting mode press the button OVERVIEW OF THE MENUS Mode AUTO Summer Co...

Page 16: ...ERATING MODES ON OFF 23 5 08 30 25 0 MODE Configuration M Mon SET Configuration 18 5 Mon 08 30 19 0 18 5 Mon 08 30 21 0 SPEED Configuration 23 5 Mon 08 00 25 0 1 3 4 5 6 7 8 9 10 A 2 AUTO MIN MED MAX...

Page 17: ...ce what TIMER program previously set to activate follow the instructions reported here below NOTE the TIMER APP program refers to the setup generated via Sabiana WiFi application TIMER Program Setup A...

Page 18: ...DAY THURSDAY FRIDAY SATURDAY SUNDAY IMPORTANT Before modifying or deleting a TIMER program it is necessary to activate it in the Activation menu see dedicated chapter TIMER Program change 07 00 22 0 M...

Page 19: ...Y THURSDAY FRIDAY SATURDAY SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY SUNDAY SECONDARY OPERATING MODES 23 5 lun 08 30 25 0 ON OFF...

Page 20: ...ycle Window contact status Remote on off status Pump alarm if available ALARMS MB Version AL1 T1 faulty probe AL2 T2 faulty probe AL3 T3 faulty probe AL4 Condensate alarm AL6 NTC probe alarm controlle...

Page 21: ...0 C dEds Dead zone central point 18 30 C dEdr Dead zone setup field 1 6 C BMS On Off under supervision mode ON OFF dS dS Set Variation Range with T MB 9 C 3 C 9 C T2 1 Status change from ventilation...

Page 22: ...tting for each day of the week until four different operation modes Just a WiFi connection is required to use the applica tion and to download our Sabiana WiFi APP that is compatible with the iOS and...

Page 23: ...delivr es par le fabricant et cit es dans la documentation du fabricant m me La conformit de la commande avec les Normes et Directives de s curit applicables est assur e uniquement et exclusivement s...

Page 24: ...on Informations Vitesse AUTOMATIQUE Menu activation Flap Swing Signalisation Swing Actif D pannage Visualisation tat Vitesse LINEAIRE ventail 1 10 Volt si disponible Menu activation IAQ Signalisation...

Page 25: ...ratifs appuyer les touches A chaque pression on a un d placement Pour Confirmer pour confirmer le choix du menu ou du mode op ra tif appuyer la touche VUE D ENSEMBLE DES MENUS Mode Automatique Mode E...

Page 26: ...MAIRES ON OFF 23 5 08 30 25 0 Configuration MODE M Lu Configuration SET 18 5 lu 08 30 19 0 18 5 lu 08 30 21 0 Configuration VITESSE 23 5 lu 08 00 25 0 1 3 4 5 6 7 8 9 10 A 2 AUTO MIN MED MAX VENTILATE...

Page 27: ...pr c demment mis en place activer se r f rer l instruc tion ci dessous NOTE Le programmeTIMER APP se r f re la configuration g n r e via APP Sabiana WiFi TIMER Configuration Programme Chaque TIMER vi...

Page 28: ...I JEUDI VENDREDI SAMEDI DIMANCHE IMPORTANT Avant de modifier ou supprimer un programme TIMER il faut qu il soit activ dans le menu Activation voir le chapitre d di TIMER Modification Programme 07 00 2...

Page 29: ...ERCREDI JEUDI VENDREDI SAMEDI DIMANCHE LUNDI MARDI MERCREDI JEUDI VENDREDI SAMEDI DIMANCHE LUNDI MARDI MERCREDI JEUDI VENDREDI SAMEDI DIMANCHE MODES OP RATIFS SECUNDAIRES 23 5 lun 08 30 25 0 ON OFF ON...

Page 30: ...cycle de anti stratification Cycle Power On Etat contacte fen tre Etat on off distance Alarme pompe si disponible ALARMES Version MB AL1 Capteur T1d fectueux AL2 Capteur T2 d fectueux AL3 Capteur T3...

Page 31: ...amp de r glage de la zone morte 1 6 C BMS Modalit sous supervision On Off ON OFF dS dS R glage de gamme de variation du SET avec T MB 9 C 3 C 9 C T2 1 Changement de l tat de ventilation refroidissemen...

Page 32: ...maine avec pour chacun jusqu quatre diff rents niveaux de fonction nement Pour utiliser l application il suffit de disposer d une connexion Wi Fi et de t l charger l APP Sabiana WiFi compatible avec l...

Reviews: