TABLE 1
C.
The minimum clearance area of a slide or diving board shall not intersect any coping or rope
and float line as shown in FIGURE
The minimum clearance area of a slide or diving board
may intersect each other provided that they are not used simultaneously
Board Minimum Clearance Area
Pool Type
“C” Dimension
“W” Dimension
I
14’
-6” (4420 mm)
5’
-0” (1524 mm)
II
14’
-6” (4420 mm)
6’
-0” (1829 mm)
III
16’
-6” (5029 mm)
6’
-0” (1829 mm)
IV
18’
-6” (5639 mm)
7’
-6” (2286 mm)
V
21’
-0” (6401 mm)
7’
-6” (2286 mm)
See Article 5 contained in ANSI/APSP/ICC-5 2011 STANDARD
FOR RESIDENTIAL INGROUND SWIMMING POOLS and refer
to FIGURE 3 and Table 1 for Minimum Water
Envelope
Dimensions AB, BC and Width at Point C.
“C” DIMENSION FOR BOARD = AB + BC
“W” DIMENSION FOR BOARD = WIDTH AT PT.C
FIGURE D