I M P O R TA N T S A F E T Y I N F O R M AT I O N
CAUTION: POWER AND SIGNAL OUTPUT CONDUITS MUST BE NON-METALLIC
ATTENTION: CONDUITS POUR PUISSANCE DE SORTIE ET SORTIE SIGNAL DOIT ETRE NON METALLIQUE
ELECTRICAL SHOCK HAZARD – SWITCH DOES NOT TURN OFF INPUT POWER.
Failure to disconnect input power before servicing can lead to serious injury, or death.
Disconnect input power before servicing.
Replace all parts and panels before reconnecting power and operating
DANGER – FAILURE TO FOLLOW THESE WARNINGS, INSTRUCTIONS, AND THE
OWNER’S MANUAL MAY RESULT IN SERIOUS INJURY OR DEATH.
Basic safety precautions shall be observed when installing and operating the connected LED Water
Feature (CLSFJB / CLSFJB2) and/or other associated equipment:
1. A qualified electrician must install the CLSFJB in accordance with the requirements of NEC
ANSI/NFPA 70 and Article 680.
2. The CLSFJB must be mounted on a flat vertical surface. The unit must be a minimum of 4
inches above the ground level, pool deck, or higher than 8 inches above the maximum pool
water level, whichever provides greatest elevation. The unit must be positioned a minimum of
4 feet (1.2 m) from the inside wall of the pool, unless separated from the pool by a solid fence,
wall, or other permanent barrier.
3.
Do not exceed the maximum electrical ratings of the LED luminaire/s housed within this
CLSFJB / CLSFJB2, or components, wiring devices, and current carrying capacity of the
conductors.
4.
This CLSFJB is intended to be used with low voltage damp rated luminaires that comply with
Article 680 of the National Electrical Code and does not require bonding due to their isolated
application design.
5. For supply connection, use only with Class 2 power units.
6. DO NOT CONNECT THIS 12V LIGHT DIRECTLY TO A 120VAC CIRCUIT - LIGHT WILL BE
DAMAGED.
7.
This device should never operate equipment that could cause property damage, bodily injury,
or death should it be activated unexpectedly.
8.
Use rain-tight or wet location hubs that comply with the requirements in the standard for
conduit, tubing, and cable fittings (UL514b) only.
9.
The conduit hub is to be connected to the power input conduit before the hub is connected to
the enclosure.