S.R.Smith SRS-TX-30 Installation Instructions Manual Download Page 5

 

79-15259-00  

www.srsmith.com 

Page 5 of 7 

Hooking up 12VAC Light to Circuit 1

 

To connect a 12VAC light to the Circuit 1 
switch, pull wires from the low voltage lighting 
product to the SRS-TX-30 through conduits 
connected to the left bottom of the SRS-TX-30.
Some lights may identify a 12VAC Hot and 
Neutral lead though this is not typical with 
12VAC low voltage lighting as there is no 
polarity.  If it does identify specific leads, then 
follow the below instructions.  
 
As illustrated, connect the light that will be 
operated by the Rocker Switch to the Light Hot 
terminal.  Connect the Light Neutral to the 
Light Neutral terminal.  Do not exceed demand 
of 30 watts @ 12V. 
 
Two UL listed wire nuts have been included to 
simplify connection of up to five lights to the 
terminal strip.

  

If conductors are stranded 

18AWG wire or smaller, use a crimping tool 
and the supplied copper wire ferrules for a 
secure installation. 

LIGHT HOT, 12VAC 

 LIGHT NEUTRAL, 12VAC 

ON 

 
 

OFF 