I N S TA L L AT I O N I N S T R U C T I O N S
R I V E R R U N S L I D E
6
SBK-RR INSTALL | 0419
Copyright ® 2019 S.R.Smith, LLC All rights reserved. |
srsmith.com
GETTING STARTED
S.R.Smith recommends that you read these instructions and helpful hints in their entirety before attempting an
installation.
IMPORTANT NOTICES:
• It is highly recommended that provision be made for future removal of the slide from the substrate, if necessary.
• The sizes of the concrete piers for the anchor supports specified herein are minimum measurements required
for the River Run, and may need to be increased due to local weather, soil conditions, frost line and/or local
building codes.
• For best performance, the recommended water flow at the slide is 80 GPM total, 40 GPM per side.
• Zoom Flume water delivery system requires a 1” PVC hose. NOTE: a ball valve in line on each side is
recommended for water flow adjustment.
• Do not construct objects or formations along or over the slide pathway that obstruct the pathway for sliders
or cause potential bodily harm. Minimum recommended head clearance above the slide pathway is 7 feet.
• Minimum River Run water envelope is 7’ wide (centered on slide) x 13.5’ long x 4’6” deep. (See Water Safety
Envelope - Page 4)
• The exit section must be installed with the correct alignment to the pool edge and should be supported at
the fiberglass landing plate.
• The surface of the slide is very slippery when wet, use caution when entering the slide. Utilization of the
provided seating assist rails is recommended for the transition from standing to sitting.