RG-10KVA

RG-10KVA

Rated voltage ..........

...................................

................  230V

Rated frequency.......

...................................

................  50Hz

Rated Power 

 ...................................

....................................

  

10kW

Rated Power F

actor  .........................

..........

.

................... 1.0

Altitude Rating  ........

..................................

............... 1000m

Rated Current  .......

...................................

................. 43.5A 

Performance Class  ...

..................................

................... G1 

Mass ..........................

..................................

.............160kgs

YEAR 2018

Automatic voltage reg

ulator

Serial No.

SINGLE PHASE 4 STR

OKE

PETROL GENER

ATOR SET

RG-10KVA

Summary of Contents for RG-10KVA

Page 1: ...Rated frequency 50Hz Rated Power 10kW Rated Power Factor 1 0 Altitude Rating 1000m Rated Current 43 5A Performan ce Class G1 Mass 1 60kgs YEAR 2018 Automatic voltage regulator Serial No SINGLE PHASE 4...

Page 2: ...Rated Power 10kW Rated Power Factor 1 0 Altitude Rating 1000m Rated Current 43 5A Performan ce Class G1 Mass 1 60kgs YEAR 2018 Automatic voltage regulator Serial No SINGLE PHASE 4 STROKE PETROL GENER...

Page 3: ...2 1 3 5 4 2 6 7 6...

Page 4: ...3 7 8 9 10 9 12...

Page 5: ...11 4 13 14 11 12 15 16 17 18 11 12 13...

Page 6: ...5 21 19 20 23 24 22 0 7 0 8mm...

Page 7: ...6 27 28 25 26 31 32 29 30 16 16 16...

Page 8: ...protection Safety equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries c Avoid accidental starting Ensure the...

Page 9: ...4 stroke oil Fuel requirement unleaded petrol Place generator on level ground keep balance NOTE WARNING Engine type Rated power Max output Voltage Frequency Displacement Fuel tank capacity Run time p...

Page 10: ...ner housing Fuel and fuel tank The engine must apply unleaded gasoline with an octane number over 86 Using unleaded gasoline will decrease the possibility of producing carbon deposit and will prolong...

Page 11: ...t emissions exceeding statutory limit values Illegal modification as such 1 Dismantle or modify any part of air intake or exhaust system 2 Modify or take off speed adjusting connection device or speed...

Page 12: ...tensional spanner which followed by specified angle or torque Fig 21 3 Maintenance of air cleaner A dirty air cleaner will limit the air into the carburetor To keep the carburetor in good working cond...

Page 13: ...The spark eliminator should be serviced at least once every 100 hour s operation so as to keep it in a sound condition WARNING The muffler is very hot during running the engine and even a long time af...

Page 14: ...g 28 and drain out fuel in the carburetor Please drain the fuel to profitable container screw down the drain bolt Turn off the engine switch first disconnect the deposit cup and empty it Reinstall the...