RX only stryker User Manual Download Page 1

User Guide

SIDNE

®

 Berchtold

ChromoVision

®

Overhead Camera

REF 240-020-839

Summary of Contents for stryker

Page 1: ...User Guide SIDNE Berchtold ChromoVision Overhead Camera REF 240 020 839...

Page 2: ......

Page 3: ...ntents EN 4 Setup and Interconnection EN 5 Quick Startup Guide EN 5 Connecting SIDNE to the Berchtold ChromoVision Camera EN 5 Mounting the EDAM EN 7 Installing the Berchtold ChromoVision Camera Drive...

Page 4: ......

Page 5: ...nel Warning To avoid potential serious injury or electric shock to the patient and or operating personnel please note the following warnings 1 To avoid potential serious injury to the user and patient...

Page 6: ...rregularity will decrease the insulation effectiveness and may result in shocks to the patient and or operating room personnel 7 Ensure that the SIDNE Berchtold ChromoVision Overhead Camera EDAM herea...

Page 7: ...se in voice activation and control of attached voice compatible devices It is indicated for use in general laparoscopy nasopharyngoscopy ear endoscopy sinuscopy and plastic surgery wherever a laparosc...

Page 8: ...the EDAM 3 Power on the SIDNE console 4 Install the Berchtold ChromoVision Camera Driver 1 0 upgrade SIDNE will restart 5 Wait for SIDNE to say SIDNE ready before powering on the Berchtold Camera Caut...

Page 9: ...f the device adapter cable to the nine pin connector on the EDAM see below 4 Connect the SIDNE interface cable to the USB connector on the EDAM see below 5 Connect the other end of the SIDNE interface...

Page 10: ...EDAM in the desired location using the velcro strips see below Installing the Berchtold ChromoVision Camera Driver Upgrade Note Read the Notes on Operation section at the end of this procedure before...

Page 11: ...n SIDNE should say Overhead Camera Connected and the EDAM LED should flash green within 20 seconds of powering on the Berchtold ChromoVision Camera A different LED output may indicate device problems...

Page 12: ...te the SIDNE Voice interface refer to the SIDNE Operating and Maintenance Manual P N 1000400988 Top Level Device Selection Control Selection Description SIDNE Ovrhd Camera Shutter Automatic Set shutte...

Page 13: ...ontrol brightness Manual Turn off automatic control of brightness Brighter Increase light level Darker Decrease light level Rotate Right Rotate Camera continuously to the right Left Rotate Camera cont...

Page 14: ...will now be ready to accept new commands Hold down the tablet button for two seconds to execute any continuous command on the tablet interface SIDNE Voice Message Definition Connected Berchtold Chromo...

Page 15: ...mera while it is completing the white balance action 3 Maximum Minimum Limits The Berchtold Camera SIDNE interface does not provide information on certain maximum minimum limits The SIDNE interface vo...

Page 16: ...dapter cable is connected to the EDAM Ensure that the device adapter cable is connected to the Berchtold ChromoVision Camera control box Power on the device EDAM LED stays solid yellow it should flash...

Page 17: ...hromoVision Camera package Caution This product is considered electronic equipment It must not be disposed of as unsorted municipal waste and must be collected separately Please contact the manufactur...

Page 18: ...cause any interference in nearby electronic equipment RF emissions CISPR 11 Class A The SIDNE Berchtold ChromoVision Camera package is suitable for use in all establishments other than domestic estab...

Page 19: ...line Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1kV differential mode 2kV common mode 0 5 1kV differential mode 0 5 1 2kV common mode Mains...

Page 20: ...ironment Immunity Test IEC60601Test Level Compliance Level Electromagnetic Environment Guidance Portable and mobile RF communications equipment should be used no closer to any part of the SIDNE Bercht...

Page 21: ...radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnet...

Page 22: ...nded below according to the maximum output power of the communications equipment Rated maximum output power W of transmitter Separation distance m according to frequency of transmitter 150 kHz to 80 M...

Page 23: ......

Page 24: ...Manufacturer Stryker Endoscopy 5900 Optical Court San Jose CA 95138 USA 1 408 754 2000 1 800 624 4422 www stryker com P11545 B 2010 01...

Reviews: