![Ruwac industriesauger NA 7-26 Instruction Manual Download Page 32](http://html1.mh-extra.com/html/ruwac-industriesauger/na-7-26/na-7-26_instruction-manual_1503263032.webp)
Commissioning
Page 32
7.3
Establishing potential equalisation (optional)
1. Attach the earthing clip to the metal hose connection spigot of
the vacuum hose.
2. Connect the handle of the potential equalisation cable to the
potential equalisation point in the working environment or on
the working machine.
3. Connect the angled socket or earthing clamp of the potential
equalisation cable to the potential equalisation point in the
working environment or on the working machine.