Russound RAVE1 Instruction Manual Download Page 1

RAVE1

RNET A/V Encoder

Instruction Manual

Copyright © 2007 Russound. All rights reserved. All trademarks are the 
property of their respective owners. Specifi cations are subject to change 
without notice. Russound is not responsible for typographical errors or 
omissions. 28-1264 

 

06/05/07

5 Forbes Road, Newmarket NH 03857 USA

Tel 603.659.5170 • Fax 603.659.5388

www.russound.com

Overview

The RAVE1 RNET A/V Encoder enables the use of a re-
mote source with a Russound RNET

®

 or other multiroom 

audio-video system. It connects to the source equipment 
and sends audio and video signals to the multiroom 
system over a single CAT-5 cable. It also provides either 
RNET or infrared control of the source equipment.

Housed in a compact surface-mount metal box, the 
RAVE1 provides connectors for RNET Link, IR emitter, 
stereo audio, and composite video. A special RJ-45 jack 
connects through the CAT-5 cable to either an RAVD1 
RNET A/V Decoder or an RNET A/V-enabled multiroom 
controller at the system end.

The RAVE1 comes with a 12 VDC power supply and 
patch cables for connecting to the source equipment.

Features

•  Enables remote location of an audio-video source for a 

multiroom system

•  Provides RNET control and feedback with an RNET 

remote source and multiroom system

•  Provides IR control of a non-RNET remote source

•  Connects to the multiroom system with a single CAT-5 

cable

•  Easily mounts on any fl at surface

Warranty

The Russound RAVE1 is fully guaranteed against all defects in materials 
and workmanship for two (2) years from the date of purchase. During this 
period, Russound will replace any defective parts and correct any defect in 
workmanship without charge for either parts or labor. For this warranty to 
apply, the unit must be installed and used according to its written instruc-
tions. If service is necessary, it must be performed by Russound. The 
unit must be returned to Russound at the owner’s expense and with prior 
written permission. Accidental damage and shipping damage are not con-
sidered defects, nor is damage resulting from abuse or from servicing by 
an agency or person not specifi cally authorized in writing by Russound.

This warranty does not cover: damage caused by abuse, accident, mis-
use, negligence, or improper installation or operation; power surges and 
lightning strikes; normal wear and maintenance; products that have been 
altered or modifi ed; any product whose identifying number, decal, serial 
number, etc. has been altered, defaced or removed.

Russound sells products only through authorized dealers and distributors 
to ensure that customers obtain proper support and service. Any Rus-
sound product purchased from an unauthorized dealer or other source, 
including retailers, mail order sellers and online sellers will not be honored 
or serviced under existing Russound warranty policy. Any sale of products 
by an unauthorized source or other manner not authorized by Russound 
shall void the warranty on the applicable product.

Damage to or destruction of components due to application of excessive 
power voids the warranty on those parts. In these cases, repairs will be 
made on the basis or the retail value of the parts and labor. To return for 
repairs, the unit must be shipped to Russound at the owner’s expense, 
along with a note explaining the nature of service required. Be sure to pack 
the unit in a corrugated container with at least three (3) inches of resilient 
material to protect the unit from damage in transit.

Before returning a unit for repair, call Russound at 603.659.5170 for a 
return authorization number. Write this number on the shipping label and 
ship to: Russound, 5 Forbes Road, Newmarket, NH 03857.

Specifi cations

 RNET A/V connector:  8-pole modular RJ-45 jack

 

Input connectors:  (1) composite video RCA jack

 

  (2) left and right audio RCA jacks

 IR emitter connector:  2-pole 0.125” (3.5 mm) TS jack

 RNET Link connector:  8-pole modular RJ-45 jack

  Power requirement:  12 VDC 1 A (power supply included)

 Mounting 

method: 

Surface

 

Dimensions:  4.25” W x 1.82” H x 2.5” D

 

  (10.8 x 4.6 x 6.4 cm)

 

Weight:  10.0 oz (284 g)

Installation

Locate the Encoder with the remote source. Install CAT-5 
or CAT-5e cable between the remote source location and 
the system controller, up to 300 feet (90 m).

Crimp an RJ-45 connector on the source end of the CAT-
5 cable, following the T568A standard as shown. Plug 
the connector into the RNET A/V jack on the Encoder. (If 
desired, use modular wall plates and RJ-45 patch cables 
for a neater appearance. Punch down the CAT-5 per the 
T568A standard and use a straight-through patch cable 
between the Encoder and the wall plate.)

Setup for RNET Control

Note:

 For RNET control of the remote source, both the 

source equipment and the system controller must be 
RNET capable. If the RNET controller does not have an 
RNET A/V jack, you will need to use an RAVD1 Decoder 
at the controller to receive signals from the Encoder.

1. Connect RNET source equipment.

 Using the sup-

plied RJ-45 patch cable, connect from an RNET Link jack 
on the source equipment to the RNET Link jack on the 
Encoder. Use the supplied RCA patch cable to connect 
from the source equipment’s audio and video outputs to 
the Encoder’s inputs.

2. Connect Encoder to RNET system.

 Crimp an RJ-45 

connector on the system end of the CAT-5 cable, follow-
ing the T568A standard as shown. With the RNET system 
turned off, plug the connector into the RNET A/V source 
input jack on the RNET system controller or RAVD1 
Decoder. (If using a wall plate, punch down the CAT-5 per 
the T568A standard and use a straight-through patch 
cable between the system and the wall plate.)

Note:

 Do not plug the CAT-5 cable into an RNET Link 

jack. It must be plugged into an RNET A/V jack on 
either the system controller or the RAVD1 Decoder.

3. Connect Decoder to RNET system.

 If using an 

RAVD1 Decoder, use a straight-through RJ-45 patch 
cable to connect from either RNET Link jack on the 
Decoder to any unused RNET Link jack on the system or 
an RNET source component. Use RCA patch cables to 
connect from the Decoder’s audio and video outputs to 
inputs on the RNET system controller.

Note:

 Do not connect the Decoder’s IR input. Doing so 

will disable RNET for the entire system.

Setup for IR Control

Note:

 If the system controller does not have an RNET 

A/V jack, you will need to use an RAVD1 Decoder at 
the controller to receive signals from the Encoder.

1. Connect source equipment.

 Attach an IR emitter 

to the infrared sensor on the source equipment and plug 
the emitter into the IR OUT jack on the Encoder. (Or use 
an IR link cable or mono patch cable with 1/8-inch [3.5 
mm] TS connectors to connect from the Encoder to the 
source equipment’s IR input jack.) Use the supplied RCA 
patch cable to connect from the source equipment’s 
audio and video outputs to the Encoder’s inputs.

2. Connect Encoder to multiroom system.

 Crimp an 

RJ-45 connector on the system end of the CAT-5 cable, 
following the T568A standard as shown. With the system 
turned off, plug the connector into the RNET A/V jack on 
the system controller or RAVD1 Decoder. (If using a wall 
plate, punch down the CAT-5 per the T568A standard 
and use a straight-through patch cable between the 
system and the wall plate.)

Note:

 Do not plug the CAT-5 cable into an RNET Link 

jack. It must be plugged into an RNET A/V jack on 
either the system controller or the RAVD1 Decoder.

3. Connect Decoder to system.

 If using an RAVD1 

Decoder, use RCA patch cables to connect from the 
Decoder’s outputs to source inputs on the system.

RNET system. 

Use a straight-through RJ-45 patch cable 

to connect from either RNET Link jack on the Decoder 
to any unused RNET Link jack on the system or an RNET 
source component.

Note:

 Do not connect the Decoder’s IR input. Doing so 

will disable RNET for the entire system.

Non-RNET system.

 Use an IR link cable or mono patch 

cable with 1/8-inch (3.5 mm) TS connectors to connect 
from the system’s IR output to the Decoder’s IR input.

Final Steps

1. Power Encoder.

 Plug the power supply into an AC 

power receptacle and connect its output lead to the 
power jack on the Encoder. If using an RAVD1 Decoder, 
power it up as well.

2. Turn on source and system.

 Power up the remote 

source and the system. Select the remote source at a 
system keypad or touchscreen and begin playing the 
source. You should hear it playing through the system.

3. Program multiroom system.

 Follow the multiroom 

system’s programming instructions to set up the remote 
source for control from the keypads and touchscreens.

RJ-45 Using T568A

Wiring Standard

Reviews: