Runco WindowWall Installation Guide
135
UNIT
STATUS
menu:
Power Supplies show
OK and power supply
fan is OK.
The power supply that is
being monitored by this
Quad Input Manager
Module is operating
normally.
This portion of the menu only shows up on
processor 1 of a Quad Input Manager Module.
If the message “PS Mon cable is not
connected” shows in this menu, there is no
power supply monitor cable connected.
Connect the RJ45 on the back of the Quad
Input Manager Module to that on the power
supply module.
The Quad Input Manager Module knows
which power supply type it has by internal
configuration jumpers. If it is reporting
failures for supplies that aren’t there, these
internal jumpers could be configured wrong.
WindowWall Layout |
Auto completes
correctly.
Position Sensors are
aligned and working
correctly.
Look at the Info Pane of each display. It shows
you its position as reported by the LCD
interface board (on the back of the display
tiles). These numbers update about once a
second.
A display tile (LCD) in service mode will not
report the correct position.
If a display on the top row shows a row other
than 1 or a display on the left side shows a
column other than 1, then light energy is
causing a false reading. This can happen with
some fluorescent lights. Cover the position
sensor hole from receiving light
Each row should show columns in order from
left to right. If the column number starts again
at 1, there is a problem either with the
receiver of that display or the transmitter of
the display next to it. Check for proper
alignment of the displays.
Similarly each column should show row
numbers in order from top to bottom.
WindowWall layout
shown in menu
matches the true
physical layout.
Comm and Video
connections are paired
correctly.
If the layout shown in the menu looks correct,
but the rows or columns are out of order
when looking at the position sensor
information in the info pane, then the COMM
connections to one or more pairs of displays
have been crossed.
If the layout shown in the menu is different
than that shown by looking at the addresses
on the info panes, then the VIDEO
connections to one or more pairs have been
crossed.
Summary of Contents for WindowWall
Page 1: ...Runco WindowWall Installation Guide...
Page 2: ......
Page 8: ...viii Runco WindowWall Installation Guide...
Page 14: ...vi Runco WindowWall Installation Guide...
Page 18: ...Safety Information 4 Runco WindowWall Installation Guide European Union Disposal Information...
Page 28: ...Off Board Equipment and Components 14 Runco WindowWall Installation Guide...
Page 56: ...Installing LCD Tiles 42 Runco WindowWall Installation Guide...
Page 62: ...Loop Through 48 Runco WindowWall Installation Guide...
Page 70: ...Menus and the Remote 56 Runco WindowWall Installation Guide...
Page 74: ...Matrix Layout Menu 60 Runco WindowWall Installation Guide...
Page 94: ...Adjusting Position 80 Runco WindowWall Installation Guide...
Page 102: ...Zoom and Viewport 88 Runco WindowWall Installation Guide...
Page 146: ...Main Menu and Submenus 132 Runco WindowWall Installation Guide...
Page 186: ...Downloading Additional Documentation and Firmware 172 Runco WindowWall Installation Guide...