134
Runco WindowWall Installation Guide
All LCD backlights turn
on with IR remote.
IR sensor is connected
Quad Input Manager
Module A is configured
and cabled to the other
Quad Input Manager
Module (per your
configuration).
Comm connection to
display tiles is good.
IR sensor must be plugged in to ‘A’ Quad
Input Manager Module.
Quad Modules must be cabled together via
RS-485
There must be one and only one Quad Input
Manager Module ‘A’
If a Quad Input Manager Module has been
newly connected, you may have to turn off
and then back on to synchronize those
displays. If in doubt, A/C power cycle the
system after all connections have been made.
“Info Pane” appears on
all displays when
menus are on. (The
“info pane” is the gray
square which shows
the display address,
position sensor
information and
information about the
target menu).
Video connection is
good.
Equalization is set within
reason.
If you see no video it all, the equalization
could be bad
If some displays do not respond, you may
have out of date firmware. All Quad Input
Manager Modules must have the same rev
level of firmware.
UNIT
STATUS
menu
appears on all displays
when the
MONITOR
button is pressed.
Properly functioning
display wall.
If a different menu appears on some displays,
you may have mismatched firmware. All Quad
Input Manager Modules must have the same
rev level of firmware, and that firmware must
be “cloned” to all 4 of the processors.
UNIT
STATUS
menu:
Temperature is within
reason.
Backlight shows OK
Voltage is >22 v
The display tile (LCD)
and its interface board
are functioning
properly.
These three items are reported to the Quad
Input Manager Module by the LCD interface
board (on the display tile) over the Comm
connection. If the voltage is 0 the voltage
meter is not functioning on the LCD interface
board (some early prototype systems did not
have this meter). If the voltage is low, there
may be too much drop in your power cables.
UNIT
STATUS
menu:
Quad Module
Temperature is within
reason and Fan is OK.
The Quad Input
Manager Module
cooling system is
operating normally.
This portion of the menu only shows up on
processor 1 of a Quad Input Manager Module.
Check for proper fan function and proper
cooling of the rack.
Summary of Contents for WindowWall
Page 1: ...Runco WindowWall Installation Guide...
Page 2: ......
Page 8: ...viii Runco WindowWall Installation Guide...
Page 14: ...vi Runco WindowWall Installation Guide...
Page 18: ...Safety Information 4 Runco WindowWall Installation Guide European Union Disposal Information...
Page 28: ...Off Board Equipment and Components 14 Runco WindowWall Installation Guide...
Page 56: ...Installing LCD Tiles 42 Runco WindowWall Installation Guide...
Page 62: ...Loop Through 48 Runco WindowWall Installation Guide...
Page 70: ...Menus and the Remote 56 Runco WindowWall Installation Guide...
Page 74: ...Matrix Layout Menu 60 Runco WindowWall Installation Guide...
Page 94: ...Adjusting Position 80 Runco WindowWall Installation Guide...
Page 102: ...Zoom and Viewport 88 Runco WindowWall Installation Guide...
Page 146: ...Main Menu and Submenus 132 Runco WindowWall Installation Guide...
Page 186: ...Downloading Additional Documentation and Firmware 172 Runco WindowWall Installation Guide...