External Control
LightStyle™ LS-12HBd Installation/Operation Manual
103
PRE
L
IMINAR
Y
Command and Response
Examples
Here are some examples of serial commands and their responses:
Serial Command List
Table 6-1 lists all supported commands.
Command
Command Data
Re
s
pon
s
e
Power query when
unit is powered on
(PWR?) [CR]
(0;PWR=1) [CR]
Set power to 0 (off)
(PWR=0) [CR]
(0;PWR=0) [CR]
Increment bright-
ness from 24 to 25
(BRT+) [CR]
(0;BRT=25) [CR]
Invalid command
(ZZZ=0) [CR]
(1;ZZZ=0) [CR]
Invalid parameter
(received string,
expected integer)
(CON=”Some string”)
[CR]
(9;CON=”Some string”)
[CR]
Table 6-1.
S
erial Command
s
S
etting
Command
Code
Read/
Write
Inc/
Dec
Min
Value
Max
Value
S
tring?
Note
s
PCE Auto Color Enable
AAC
R/W
No
0
1
No
0 = Off; 1 = On
PCE Diagnostic Color
AAD
R/W
No
0
6
No
0 = White
1 = Red
2 = Green
3 = Blue
4 = Yellow
5 = Cyan
6 = Magenta
PCE Blue x
ABX
R/W
Yes
-100
100
No
PCE Blue y
ABY
R/W
Yes
-100
100
No
Adjustment Mode
ADJ
R/W
No
0
2
No
0 = Both
1 = Left
2 = Right
PCE Green x
AGX
R/W
Yes
-100
100
No
PCE Green y
AGY
R/W
Yes
-100
100
No
Apply Image Alignment Values
AIA
R/W
No
0
1
No
0 = Off; 1 = On
Altitude
ALT
R/W
No
0
1
No
0 = Auto
1 = High
Advanced Color Temp Mode
Enable
AME
R/W
No
0
1
No
0 = Off; 1 = On
Auto New Firmware Check
ANF
R/W
No
0
1
No
0 = Off; 1 = On
Auto Power Off Enable
APE
R/W
No
0
2
No
0 = Off; 1 = On; 2 = No Signal
Auto Power Off Timer
APT
R/W
Yes
1
24
No
Auto Perform Upgrade
APU
R/W
No
0
1
No
0 = Off; 1 = On