background image

 

 

 

 

 

 

RG-WS6024 Series Wireless controller 

Hardware Installation and Reference Guide V1.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for RG-WS6024 Series

Page 1: ...RG WS6024 Series Wireless controller Hardware Installation and Reference Guide V1 00...

Page 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any n...

Page 3: ...site https www ruijienetworks com Technical Support Website https ruijienetworks com support Case Portal http caseportal ruijienetworks com Community http community ruijienetworks com Technical Suppor...

Page 4: ...able 1 1 RG WS6024 Model 10 100 1000 Base T Auto sensing Ethernet Port SFP Port 1000Base X SFP Port Console Port USB Port Expansion Module Slot Pluggable Power Slot RG WS6024 24 PoE 2 2 Combo 1 1 1 Du...

Page 5: ...maximum power input of 30W The maximum output power is subject to the configured power supplies The available number of PoEs is determined by PoE output power and PoE input power in practice Power Co...

Page 6: ...ck panel it provides 2 power module slots and 2 expansion module slots Figure 1 1 Appearance of RG WS6024 Front Panel Figure 1 2 Front Panel of RG WS6024 Note 1 System status LED 2 Expansion module 1...

Page 7: ...E AC500P RG M5000E AC500P HVDC Platform RG WS6024 RG WS6024 Rated Voltage Range 100V to 240V 50 60Hz 240V Maximum AC Input Voltage Range 90V to 264V 50 60Hz 192V to 290V PoE Power Single power supply...

Page 8: ...ng Supported Redundant Power Supplies 1 1 Over Voltage Protection 54V 58V to 66V 12V 13 2Vto 15 6V Over Current Protection 54V 7 8A to 10A 12V 11A to 14A Over Temperature Protection Supported Current...

Page 9: ...ut The wireless controller can be powered by one power module or by two power modules When both two modules are available the wireless controller is powered in the current sharing mode When the wirele...

Page 10: ...ireless controller is operational Solid yellow Temperature warning Check the working environment of the wireless controller immediately Solid red The wireless controller is faulty Expansion module sta...

Page 11: ...ow The port is receiving or transmitting traffic at 10 100 Mbps Port PoE status LED 1 24 Off PoE is not enabled Solid green PoE is enabled The port is operational Solid yellow The port has a PoE fault...

Page 12: ...n performing electric operations Relevant operators must be qualified Before installing the device carefully check any potential danger in the surroundings such as ungrounded power supply and damp wet...

Page 13: ...ormal ventilation After various cables have been connected they should be arranged into bundles or placed on the cabling rack to avoid blocking the air inlets It is recommended to clean the wireless c...

Page 14: ...5 m Particles m3 3 5 106 Diameter 5 m Particles m3 3 104 Apart from dust the salt acid and sulfide in the air in the equipment room must also meet strict requirements as such poisonous substances may...

Page 15: ...protective grounding wire should be at least 0 75 mm2 18 AWG Use the 3 core power supply line The sectional area of each pin should be at least 0 75 mm2 or 18 AWG Lightning Grounding The lightning pr...

Page 16: ...nd the sensitive component along which cable the interference conducts from one unit to another Conducted interference often affects the power supply of the equipment but can be controlled by a filter...

Page 17: ...fore Installation Before installation please confirm the following points Whether ventilation requirements are met for the wireless controller Whether the requirements of temperature and humidity are...

Page 18: ...launch pad and high frequency large current devices If necessary electromagnetic shielding should be adopted For example use interface cables to shield cables 100 meter network cables should be laid...

Page 19: ...ounting the Wireless controller on the Wall The RG WS6024series wireless controller can be mounted on the wall as shown in the following figure Attach the mounting brackets to the wireless controller...

Page 20: ...Figure 3 5 Figure 3 4 Attaching the Wireless Controller on the Wall 3 3 3 Mounting the Wireless controller on a Table Attach the four rubber feet to the recessed areas on the bottom of the wireless co...

Page 21: ...the power supply so as to avoid any personal injury or damage to the component due to connection errors Check that the ground line is connected Check that the cables and power input cables are correct...

Page 22: ...port of the PC Step 2 Connect the end of the console cable with RJ45 to the console port of the wireless controller Setting Heper Terminal Parameters Step 1 Start the PC and run the terminal simulati...

Page 23: ...layed Choose the serial port used currently in the column use when connecting Figure 4 3 After choosing the serial port click OK to display the serial port parameter setting interface set the baud rat...

Page 24: ...ntroller The HyperTerminal is started and the parameter settings are correct 4 2 2 Checking after Program Startup Recommended After power on you are recommended to perform the following checks to ensu...

Page 25: ...tor is not on after the wireless controller is started The power supply module does not supply power The power cable is in loose contact Check whether the power socket at the equipment room is normal...

Page 26: ...ed twisted pair cable is faulty The length of the cable exceeds 100 m The port has special configuration that has no common working mode with the connected wireless controller Replace the twisted pair...

Page 27: ...all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Four Twisted Pairs of the 1000BASE T In addition to the above cables the 10...

Page 28: ...or the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic diagram is shown in Figure A 4 Figure A 4...

Page 29: ...DDM Yes No Intensity of Transmitted Light dBm Intensity of Received Light dBm Min Max Min Max FE SFP LX MM1310 1310 MMF 62 5 125 2km Yes 22 14 30 14 FE SFP LH15 SM1310 1310 SMF 9 125 15km Yes 15 8 28...

Page 30: ...ules must be used in pairs e g FE SFP LX20 SM1310 BIDI and FE SFP LX20 SM1550 BIDI Table B 4 Models and Technical Specifications of the Mini GBIC GT Module The existing SFP copper module Standard 1000...

Page 31: ...pe Connector Type Copper Cable Length m Conductor Wire Diameter AWG Data Rate Gb s DDM Yes No XG SFP CU1M Passive SFP 1 28 10 3125 No XG SFP CU3M Passive SFP 3 28 10 3125 No XG SFP CU5M Passive SFP 5...

Page 32: ...that the PE terminal of the power arrester has been well grounded After connecting the wireless controller AC power plug to the socket of the power arrester lightning protection cable row lightning p...

Page 33: ...g terminal of the wireless controller 3 Use the multimeter to check whether the grounding line for the arrester is in good contact with the wireless controller grounding terminal and the framework 4 A...

Page 34: ...hernet port to the OUT end Poor arrester grounding The length of the grounding line should be as short as possible to ensure that it is in good contact with the wireless controller grounding terminal...

Page 35: ...e greater than seven times their respective diameters The bend radius of a common coaxial cable should be greater than seven times its diameter The bend radius of this type of cables that often bend o...

Page 36: ...traversed by cables should have a smooth and fully rounding surface or an insulated lining Proper buckles should be selected to bundle up cables It is forbidden to connect two or more buckles to bund...

Page 37: ...guide rails of moving parts The power cables connecting moving parts such as door grounding wires should be reserved with some access after assembled When the moving part reaches the installation pos...

Page 38: ...bunches with cables in cable bunches clean and straight Binding by using buckles should be performed according to Table D 1 Cable Bunch Diameter mm Binding Space mm 10 80 150 10 30 150 200 30 200 300...

Page 39: ...as away from dust If the dust is unavoidable keep the door and window away from the pollution source The machine room should be away from the residential area Otherwise the machine room should meet th...

Reviews: