Hardware Installation and Reference Guide Product Overview
Indicator
Panel
Identification
Status
Meaning
Switch status indicator
Status
Off
The system is not powered up.
Solid red
1)
One of the modules of the system fails.
2)
There are less than 2 fans.
3)
The internal temperature exceeds the warning
working temperature, and the switching service
resets.
Blinking green.
The system is initializing.
Solid green
The system is operational.
Solid yellow
1) The temperature gets to the warning threshold.
2) Only 2 fans are in the position.
3) One of the dual powers is not connected with the
AC power cord.
Switch locator indicator
ID
Off
Device location is disabled.
Solid blue
Device location is enabled.
MGMT port indicator
MGMT
Off Link indicator
The port is not connected.
Yellow Link
indicator
The port is connected at 10M/100M/1000M bps.
Green Act
indicator
The port is connected at 10M/100M/1000M bps.
Blinking green Act
indicator
The port is transmitting or receiving data at
10M/100M/1000M bps.
QSFP+ port status
indicator
5F-28F
(4 x 10G
mode)
Off
The port is not connected.
Solid green
The port is connected at 10Gbps.
Blinking green.
The port is transmitting or receiving data.
1F-32F
(1 x 40G
mode)
Off
The port is not connected.
Solid green
The port is connected at 40Gbps.
Blinking green.
The port is transmitting or receiving data.
Power Supply
The RG-S6220-H series switches support power supply the RG-M6220-AC460E-F. The smart power supply module
supports power management, and the host can read input power, input current, and temperature in real time. The
power supply module supports hot swapping.
The RG-S6220-H series switches support 1+1 power supply redundancy. To improve the stability and reliability of
the entire system, it is recommended to configure 1+1 power supply redundancy. When the two power supply
modules work normally, the switch is in the status of current sharing.
It requires at least one power supply module to work normally. Filler panels need to be installed in the unoccupied
power supply module slots to ensure ventilation and heat dissipation and avoid dusts.
Heat Dissipation
The working temperature of the RG-S6220-32QXS-H switches is 0
º
C to 45
º
C or 32
º
F to 113
º
F, and the heat
dissipation design needs to ensure the stability, safety and maintainability in such environment. The RG-S6220-H