background image

 

 

Figure 1-14 Front Panel of the RG-S2928G-24P 

 

Note: 

1. USB2.0 port 

2. RJ45 console port 

3. System status indicator 

4. 10/100/1000 Base-T adaptive Ethernet 

port indicator 

5. RJ45 10/100/1000 Base-T adaptive 

Ethernet port (all of the 24 ports support 

802.3af and 802.3at PoE) 

6. 100 Base-FX/1000 Base-X SFP port 

7. 100 Base-FX/1000 Base-X SFP/2.5 G stack port 

8. 100 Base-FX/1000 Base-X SFP/2.5 G stack port indicator 

9. PoE mode indicator 

10. PoE/switched mode indicator switchover button (By default, 

the switch port indicator indicates the switched mode. You can 

press this button to switch the status of indicator between 

switched mode and PoE mode.)   

Back Panel 

Figure 1-15 Back Panel of the RG-S2928G-24P 

 

Note: 

1. Grounding pole 

2. Fan outlet 

3. Three-hole AC power receptacle 

4. Power cord retention clips 

Power Supply 

The RG-S2928G-24P can be powered either with AC power or DC power.

 

 

AC input: 

Rated voltage range: 100 V to 240 V 

Maximum voltage range: 90 V to 264 V 

Frequency: 50 Hz to 60 Hz 

Rated current: 6.8 A (Max) 

Power cord: 10A power cord 

 

 

HVDC input: 

Maximum voltage range: 192 V to 290 V 

Rated current: 3.5 A to 2.5 A 

Power cord: 10A power cord

 

Summary of Contents for RG-S2928G-12P

Page 1: ...RG S2900G E Series Switch Hardware Installation and Reference Guide V1 25...

Page 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any n...

Page 3: ...taining Technical Assistance Ruijie Networks Website http www ruijienetworks com Service Email service_rj ruijienetworks com Technical Support http www ruijienetworks com service aspx Technical Suppor...

Page 4: ...s Model 10 100 1000 Base T Adaptive Ethernet Port SFP Port Console Port Extension Module Slot RG S2928G E 24 4 1 N A RG S2952G E 48 4 1 N A RG S2928G 12P 24 4 1 N A RG S2928G 24P 24 4 1 N A The four S...

Page 5: ...ge 90 V to 264 V Frequency 50 60 Hz Rated current 2A HVDC input Maximum voltage range 192 V to 290 V Rated current 0 2 A to 0 12 A EEE Not supported on the RG S2928G E V1 00 and later Supported on the...

Page 6: ...rnet adaptive ports and four SFP ports Figure 1 1 shows the appearance of the RG S2928G E Figure 1 1 Appearance of the RG S2928G E Front Panel Figure 1 2 Front Panel of the RG S2928G E Note 1 USB2 0 p...

Page 7: ...cord 10A power cord Heat Dissipation The RG S2928G E full gigabit switch is designed with no fans To ensure good dissipation sufficient space 10 cm distance from both sides and the back panel of the c...

Page 8: ...G S2928G E V2 00 and later support 100Base FX 25F 28F Off The port is NOT connected Solid green The port is connected Blinking The port is transmitting or receiving data 1 2 RG S2952G E Technical Spec...

Page 9: ...ximum voltage range 192 V to 290 V Rated current 0 3 A to 0 17 A EEE Not supported on the RG S2952G E V1 00 and later Supported on the RG S2952G E V2 00 and later PoE Not supported Power Consumption L...

Page 10: ...4 shows the appearance of the RG S2952G E Figure 1 4 Appearance of the RG S2952G E Front Panel Figure 1 5 Front Panel of the RG S2952G E Note 1 USB2 0 port 2 RJ45 console port 3 RJ45 10 100 1000Base T...

Page 11: ...nt 1 5 A Power cord 10A power cord HVDC input Maximum voltage range 192 V to 290 V Rated current 0 3 A to 0 17 A Power cord 10A power cord Heat Dissipation The RG S2952G E full gigabit switch adopts f...

Page 12: ...1 48 Off The port is NOT connected Solid green The port is connected at 1000Mbps Solid yellow The port is connected at 100 10Mbps Blinking The port is transmitting or receiving data 100 Base FX 1000 B...

Page 13: ...X 1000 Base T 100 Base FX and 2 5 G stacked SFP module USB Port One Type A USB2 0 interface Power Supply AC input Rated voltage range 100 V to 240 V Maximum voltage range 90 V to 264 V Frequency 50 60...

Page 14: ...e RG S2928G 12P Front Panel Figure 1 10 Front Panel of the RG S2928G 12P Note 1 USB2 0 port 2 RJ45 console port 3 System status indicator 4 10 100 1000Base T adaptive Ethernet port indicator 5 RJ45 10...

Page 15: ...current 3 A Power cord 10A power cord HVDC input Maximum voltage range 192 V to 290 V Rated current 2 A to 1 5 A Power cord 10A power cord Heat Dissipation The RG S2928G 12P switch adopts axial fans f...

Page 16: ...tem is being initialized Solid green The system is operational Solid yellow System over temperature warning Solid red Serious over temperature the system will stop working forcibly by itself Or the fa...

Page 17: ...Base T Mini GBIC GT 2 5 G stack module GE SFP STACK1 6M The supported module type may change at any time Contact us for the detailed change information SFP Port Support 1000 Base X 1000 Base T 100 Bas...

Page 18: ...pport adjustment of fan speed and warning of fan troubles Temperature Warning Supported EMC Standards GB9254 1998 Safety Standards GB4943 2001 Dimensions W x D x H 440 mm x 260 mm x 43 6 mm Weight Les...

Page 19: ...hover button By default the switch port indicator indicates the switched mode You can press this button to switch the status of indicator between switched mode and PoE mode Back Panel Figure 1 15 Back...

Page 20: ...ly of the RG S2928G 24P switch is designed to support the IEEE802 3af and 802 3at standards It uses Alternative A that is uses pins 1 2 and 3 6 to transmit power LED Indicators Indicator Faceplate Mar...

Page 21: ...1 24 Off No PoE power supply Solid green PoE is operational Solid yellow Abnormal PoE power supply 100Base FX 1000Base X Stack port indicator 25F 28F Off The port is NOT connected Solid green The port...

Page 22: ...e turn off all power supplies and dismantle all power modules 2 1 3 Electric Safety Observe local regulations and specifications when performing electric operations Relevant operators must be qualifie...

Page 23: ...rable life of the equipment the installation site must meet the following requirements 2 2 1 Ventilation Requirements For the RG S2900G E series you must ensure that sufficient space 10 cm distance fr...

Page 24: ...reat to the running of the equipment The indoor dust falling on the equipment may be adhered by the static electricity causing bad contact of the metallic joint Such electrostatic adherence may occur...

Page 25: ...is for the stable and reliable operation of the RG S2900G E series It is the chief condition to prevent lightning stroke and resist interference Please carefully check the grounding conditions on the...

Page 26: ...depending on the type of the transmission path When the energy often RF energy from a component arrives at a sensitive component via the space the energy is known as radiated interference The interfer...

Page 27: ...e 2 4 List of Installation Tools Common tools Philips screwdriver flathead screwdriver related electric cables and optical cables bolts diagonal pliers straps Special tools Anti static tools Meters Mu...

Page 28: ...ing points Whether ventilation requirements are met for the switch Whether the requirements of temperature and humidity are met for the switch Whether power cables are already laid out and whether the...

Page 29: ...ry electromagnetic shielding should be adopted For example use interface cables to shield cables 100 meter network cables should be laid inside the equipment room and outdoor cabling of such cables is...

Page 30: ...that the ground line is connected Check that the cables and power input cables are correctly connected Check that the 100 meter cables are laid out inside the equipment room In the case of external c...

Page 31: ...l port of the PC Step 2 Connect the end of the console cable with RJ45 to the console port of the switch Setting HyperTerminal Parameters Step 1 Start the PC and run the terminal simulation program on...

Page 32: ...layed Choose the serial port used currently in the column use when connecting Figure 4 3 After choosing the serial port click OK to display the serial port parameter setting interface set the baud rat...

Page 33: ...rminal is started and the parameter settings are correct 4 2 2 Checking after Program Startup Recommended After power on you are recommended to perform the following checks to ensure the normal operat...

Page 34: ...icator is not on after the switch is started The power supply module does not supply power The power cable is in loose contact Check whether the power socket at the equipment room is normal and whethe...

Page 35: ...The PoE port cannot be powered The PoE function is not enabled The connected twisted pair is faulty The PD that is the powered device for example AP connected to the port does not comply with the 802...

Page 36: ...1 TP0 1 TP0 2 TP0 2 TP0 2 TP0 2 TP0 3 TP1 3 TP1 3 TP1 3 TP1 6 TP1 6 TP1 6 TP1 6 TP1 4 TP2 4 TP2 4 TP2 4 TP2 5 TP2 5 TP2 5 TP2 5 TP2 7 TP3 7 TP3 7 TP3 7 TP3 8 TP3 8 TP3 8 TP3 8 TP3 In addition to the...

Page 37: ...OTD 3 IRD 6 OTD 6 IRD 6 OTD 6 IRD 2 Optical Fiber Connection For the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The...

Page 38: ...sity of Received Light dbm MAX Standard Complian ce MINI GBIC S X MM850 850 Multi mode fiber 62 5 62 5 50 0 50 0 160 200 400 500 220 m 275 m 500 m 550 m 4 17 IEEE802 3 MINI GBIC L X SM1310 1310 Multi...

Page 39: ...as away from dust If the dust is unavoidable keep the door and window away from the pollution source The machine room should be away from the residential area Otherwise the machine room should meet t...

Reviews: