Ruijie RG-NBS5100 Series Switches Hardware Installation and Reference Guide
Product Overview
6
Note:
1. Reset button
2. System status LED
3. 10/100/1000 Base-T Ethernet port
4. 1000Base-X SFP port
The switch reboots after the reset button is pressed for less than 2 seconds.
The switch restores the default factory settings after the reset button is pressed for more than 5 seconds (until the
status LED blinks).
Back Panel
Figure 1-3 Back Panel of RG-NBS5100-24GT4SFP
Note:
1. Power cord retention clips
2. Three-hole AC power receptacle
3. Protective earthing terminal
This device relies on the separate protective earthing terminal.
The device installation shall be permanently connected to building earth by a skilled person.
The device shall be intended to be used in a location having equipotential bonding(such as a telecommunication
centre, a dedicated computer room, or a restricted access area).
Heat Dissipation
RG-NBS5100-24GT4SFP adopts side-to-rear heat dissipation, thereby ensuring normal function of the device in the
specified environment. 10 cm distance space should be reserved at both sides and the back plane of the cabinet to
allow air circulation. It is recommended to clean the device once every 3 months to avoid dust from blocking vents.
Figure 1-4 Flow Scheme of Heat Dissipation