Ruijie RG-AP710 Series Hardware  Installation And Reference Manual Download Page 1

 

 
 
 
 
 

Ruijie RG-AP710 Series Access Points 

 

Hardware Installation and Reference Guide V1.00

Summary of Contents for RG-AP710 Series

Page 1: ...Ruijie RG AP710 Series Access Points Hardware Installation and Reference Guide V1 00...

Page 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption statement This document is provided as is The contents of this document are subject to change without any n...

Page 3: ...ty https community ruijienetworks com Technical Support Email service_rj ruijienetworks com Skype service_rj ruijienetworks com Related Documents Documents Description Configuration Guide Describes ne...

Page 4: ...ac 5 15 GHz to 5 35 GHz 5 47 GHz to 5 725 GHz 5 725 GHz to 5 85GHz Depending on which country the AP is installed Antenna Built in antenna Spatial Streams 2 4G supports 2 spatial streams 5G supports...

Page 5: ...o 158 F Operating 5 to 95 RH non condensing Humidity Storage 5 to 95 RH non condensing Installation Ceiling wall mount IP Rating IP41 Safety Standards GB4943 IEC 60950 1 EMC Standards GB9254 EN301 489...

Page 6: ...with the AP Blinking blue 3Hz Normal operation at least one wireless client is associated with the AP Pressed for less than 2s Restart the device Reset button Pressed for more than 3s Restore default...

Page 7: ...r adapters If needed you can buy them from Ruijie To use a PoE device make sure it supports the IEEE 802 3af at PoE standard 1 5 Cooling Solution The AP adopts fanless design Leave sufficient space at...

Page 8: ...the AP away from EMI sources such as large radar stations radio stations and substations Do not subject the AP to unstable voltage vibration and noises Keep the AP at least 500 meters away from the s...

Page 9: ...trical leakage and sometimes may lead to change of mechanical properties of materials and corrosion of metal parts Low relative humidity may dry and shrink insulation sheets and cause static electrici...

Page 10: ...the power actually consumed by the system The input power for the RG AP710 should be greater than 15 W Please use Ruijie recommended power adapters Please use Ruijie certified PoE injectors 2 8 Insta...

Page 11: ...he above listed items are for general situations which may vary in the actual shipment The purchase order shall prevail in any case Please check each item carefully according to the packing list or pu...

Page 12: ...te meets temperature and humidity requirements The installation site is equipped with proper power supply Network cables are in place The installation site meets all described requirements The custom...

Page 13: ...Tap wall anchors into the holes and drive screws through the mounting bracket into the anchors to fix the bracket See Figure 3 1 Figure 3 1 Attaching the Mounting Bracket on the Ceiling 2 Align the sq...

Page 14: ...e slots After installation verify that the AP is securely fastened Wall Mount 1 Drill four 6 mm diameter holes 53 mm apart on the wall with the arrow on the mounting bracket facing up Tap wall anchors...

Page 15: ...arrow on the mounting bracket until it clicks into place See Figure 3 6 Figure 3 6 Mounting the AP on the Bracket The square feet should fit easily into the mounting slots Do not forcibly push the AP...

Page 16: ...ernet cables 3 6 Removing the Access Point 1 If the hidden lock is enabled attach the front part of the key to the edge of the mounting bracket keep the Ruijie logo of the key toward the top panel of...

Page 17: ...t UTP STP to the LAN1 PoE port on the AP See Appendix A for supported wiring of twisted pairs By default baud rate is set to 9600 data bit 8 parity none stop bits 1 and flow control none on the consol...

Page 18: ...der the AP and run in straight line 3 9 Checking after Installation Checking the Cabinet Make sure the external power supply matches the specifications of the patch panel in the cabinet After installa...

Page 19: ...ected to a PC for debugging verify that the PC and PoE switch are properly grounded 4 1 1 Powering up the AP 4 1 1 1 Checking before power up Verify that the power supply is properly connected Verify...

Page 20: ...o remotely monitor the configurations and status of the AP You can login in to the AP via Telnet and use monitoring related commands to maintain the AP 5 1 1 Remote Maintenance If the AP operates as a...

Page 21: ...the cable is connected properly 2 If you use a power adapter verify that the power adapter is connected to an active power outlet and then verify that the power adapter works properly Ethernet port i...

Page 22: ...the blinking persists for an hour it indicates the device initialization fails and the device is faulty LED keeps blinking orange Fit AP mode Sometimes the AP performs firmware upgrade after power on...

Page 23: ...imum distance of 100 meters 328 feet 1000BASE T requires all four pairs of wires be connected for data transmission as shown in Figure A 1 Figure A 1 1000BASE T Connection 10BASE T uses Category 3 4 5...

Page 24: ...he bend radius should be 10 times the overall diameter The minimum bend radius of a high speed cable such as an SFP cable should be 5 times the overall diameter of the cable If the cable is constantly...

Page 25: ...ation is not affected and no damages occur to the device and cables during debugging Do not bind power cords to the rails for moving parts Leave a certain length of the cable connecting moving parts s...

Page 26: ...to fasten terminals Bundle cables of the same type and running in the same direction into groups Keep cables clean and straight Cables shall be tied according to the following table Diameter of Cable...