RuiDeng DPS8005 Operating Instructions Manual Download Page 1

Constant Voltage / Constant Current

 

Programmable

 

Power Supply

 

Model: DPS8005

 

General Information

 

 

The programmable Power supply

 

offers constant Current and constant Voltage and combines 

both analog and digital technology in an integrated and advanced design.

 

The fully adjustable output ranges from 0

-

80.00V in 0.01V (10mV) steps and the fully adjustable 

Current Limited output ranges from 0

-

5.100A in 0.001A (1mA) steps. 

 

The unit offers non

-

volatile power off parameter storage and 10 programmable preset memory 

Data Groups with a quick recall function for groups 1 and 2.

 

The digital control interface offers a comprehensive feature set not available on analog only 
power supplies. The keypad and rotary control offer simple input and selection of all required 
settings whilst the full colour LCD offers detailed display of the extensive but easily read 
information relating to system operation and performance. Items that can be displayed include a 
precision voltmeter and ammeter, preset Voltage, output Voltage, preset Current Limit, output 
Current, output Power and Data Group selection parameters and menus. Notification icons and 
text include indications such as output enabled or disabled, Constant Current or Constant Voltage 
mode of operation, abnormal condition warning, keypad locked or unlocked state and the Data 
Group in use. The Data Setting interface allows full adjustment of Over

-

Current, Over

-

Voltage and 

Over

-

Power protection values, Data Group settings and LCD brightness. The unit offers a 

technologically advanced design presented in a very compact size that is both visually appealing 
and easy to operate.

 

 

Technical parameters

 

Input Voltage range:

  

10.00

-

90.00V 

  

 

                    

    Output Voltage range:

  

0

-

80.00V

 

Output Current:

 

0

-

5.100A 

                                        

    Output Power range: 0

-

408W

    

Product Weight: 150g 

                       

           

          

    Display module size: 79*43*54(mm) (L*W*H)

 

Display module enclosure cutout size:

  

71mm*39mm 

 

Output Voltage resolution: 0.01V (10mV)                Output Current resolution: 0.001A

 

(1mA)

 

Output Voltage accuracy: ± (0.5% + 1 digit)              Output Current accuracy: ± (0.5% + 2 digits)

 

NOTES: 

 

1.

 

You must ensure that the input Voltage is at least 1.1 times higher than the output Voltage. 

 

2.

 

When the unit mounted in an enclosure it is absolutely vital to ensure appropriate 
ventilation for heat dissipation. 

 

 

 

 

Summary of Contents for DPS8005

Page 1: ...eset Current Limit output Current output Power and Data Group selection parameters and menus Notification icons and text include indications such as output enabled or disabled Constant Current or Constant Voltage mode of operation abnormal condition warning keypad locked or unlocked state and the Data Group in use The Data Setting interface allows full adjustment of Over Current Over Voltage and O...

Page 2: ...t NEVER under any circumstances be connected to this unit Apart from the immediate and potentially fatal risk of electrocution this will cause major irreparable damage to the unit Panel description 1 Voltage setting Up Arrow Shortcut to recall M1 Data Group 2 Data entry Extract data from the specified Data Group Store value into the specified Data Group 3 Current Limit setting Down Arrow Shortcut ...

Page 3: ... Data Group memory number when selected and output enabled disabled icon Set the output Voltage and output Current Limit via the Main Interface Press V key to enter the Voltage setting mode The Voltage setting numeric value will be highlighted by the cursor Press the rotary control to place the cursor at the required character of the numerical value you wish to change Further presses of the rotary...

Page 4: ...iew and edit After completing the desired setting press and hold the SET key until the Data Group number is shown on the right hand side of the screen Pressing the set key again returns to the Data Group menu options Selecting M Pre ON OFF Press V or A to step up or down through the menu options to select M PRE and then press the rotary control Turn the rotary control to select the number of the D...

Page 5: ...sable the Output Locking the keypad to avoid accidental operation The keypad operation can be disabled to avoid accidental operation and unwanted changes At any time you can simply press and hold the rotary control for more than 3 seconds to either lock or unlock all keys The status of the key lock will be displayed at all times via the lock icon on the right side of the screen Keypad locked is in...

Page 6: ...s and hold the SET key more than 3 seconds M0 will be displayed on the right side of the screen Turning the rotary control allows selection of the required Data Group M1 to M9 To activate the selected Data Group press the SET key ...

Reviews: