7.1 Alarm Information Description
During the operation of the main board, an abnormal situation may be encountered to
generate an alarm, and a corresponding protection action is generated to protect the machine.
Alarm information includes system error, limit trigger, reset error, collision alarm, excessive
following error, small capacitance value, encoder error, servo alarm, laser alarm, machine
protection, etc. When an error occurs, the corresponding error will be indicated on the panel. If
an error occurs, please follow the error prompt to eliminate the error before running the system,
otherwise it may affect the normal operation of the system.
7.1.1 System error
When the system fails and cannot run normally, a system error will be displayed and the
system will stop moving. In this case, you need to power on the mainboard again. If the system is
incorrectly displayed after repeated power-on, the mainboard cannot be used normally.
7.1.2 Upper and lower limit trigger
When the Z-axis limit is enabled, when the limit switch is triggered, the limit trigger is
displayed. If the cutting head does not trigger the limit switch and still displays the limit trigger, it
may be the situation as following:
The limit polarity setting is incorrect. Please modify the polarity of the limit switch.
The limit switch wiring is incorrect, please connect correctly;
The limit switch is damaged, or the limit switch output voltage is incorrect. Please
replace the limit switch.
7.1.3 X
、
Y
、
U
、
A Hard limit trigger
When the limit is enabled, when the limit switch is triggered, the limit trigger is displayed. If
the limit switch is not triggered and the limit trigger is still displayed, it may be the situation as
following:
The limit polarity setting is incorrect. Please modify the polarity of the limit switch.
The limit switch wiring is incorrect, please wire it correctly;
The limit switch is damaged, or the limit switch output voltage is incorrect. Please
replace the limit switch.