The interface displays the current board authorization status. If [Authorization is not
activated] is displayed, it needs to be activated on the PC software. When the activation is
successful, the interface displays [Authorization activated], and the authorization code is
refreshed. [Change Authorization Code] option becomes valid. When the license key needs to be
updated after the license card expires, users select the [Change Authorization Code] option and
press the [Enter] key to enter the Change Authorization Code interface. After entering the correct
authorization code, select the [Confirm Authorization Code] option and press [Enter]. Press [Exit]
to return to the previous interface.
3.8 Functions
Function include: servo calibration, capacitance calibration, auto-tuning, axis reset, auxiliary
functions, alarm logging, keypad lock, diagnostics, HMI firmware upgrades and more.
3.8.1 Axis reset
Axis reset includes reset operations such as system reset, X-axis reset, Y-axis reset, Z-axis
reset, XY-axis reset, U-axis reset, and A-axis reset. When the system is reset, the Z axis will be
reset first. After the Z axis reset is completed, the XY axis will be reset at the same time, which is
the same as the reset function on the wireless handset. When the XY axis is reset, only the XY
axis is reset at the same time. Others are reset for a separate axis and only the corresponding
axis is reset.