Tumbler MPR 300
13
The lid cannot be opened when there is a vacuum in the
machine or if it has not yet been fully aerated.
If you interrupt a program by pressing "Pause", you will be
prompted to aerate when "Open lid" is actuated. Only af-
ter the drum has been evacuated will you be able to open
the lid by actuating it again.
The drum can be set to any position between -10° and
100° (= discharging position) so that it can be used for
any operating process.
The tablet PC may only be operated by finger touch or
with a stylus. Using any objects (e.g. knife) for operation
is prohibited!
4
Cleaning instructions
The Tumbler has been designed to allow for complete cleaning of all
parts that come into contact with the food product.
4.1
Safety instructions
•
Also observe Chapter 1 Safety instructions!
•
The cleaning staff must notify the supervisor immediately of any
defects on the machine!
•
The cleaning staff must use the specified cleaning agents and
disinfectants!
•
Germ reduction is achieved only by correct cleaning and subse-
quent disinfection!
•
Appropriate material (e.g. brushes, rags) is required and must be
provided for the proper procedures of the above!
•
Cleaning products and disinfectants approved for the food prod-
uct area and suitable to remove contamination (e.g. protein, lime-
scale) must be used!
•
The cleaning agents and disinfectants must be prepared to a so-
lution as described in the product data sheet of the manufac-
turer!