background image

RuggedSwitch™ RS950G

Hardware Installation Guide

Revision 100 - November 2, 2012

www.RuggedCom.com

Summary of Contents for RuggedSwitch RS950G

Page 1: ...RuggedSwitch RS950G Hardware Installation Guide Revision 100 November 2 2012 www RuggedCom com...

Page 2: ...RuggedBackbone RuggedRated and eRSTP are trademarks of RuggedCom Inc ROS RuggedRouter and RuggedSwitch are registered trademarks of RuggedCom Inc Other designations in this manual might be trademarks...

Page 3: ...16 2 3 2 DC Power Supply Wiring and Grounding 17 2 3 3 Failsafe Output Wiring 17 2 3 4 Dielectric Strength Testing 18 2 4 Console Port Wiring 18 3 Ports 19 3 1 Copper Ports 19 3 1 1 Transient Protect...

Page 4: ...HSR with PRP Application 12 1 5 RS950G Front Panel Description 13 1 6 Bottom Panel Description 13 2 1 Panel Mounting 14 2 2 DIN Rail Mounting 15 2 3 AC Power Supply Wiring and Grounding 16 2 4 DC Pow...

Page 5: ...ng Environment 21 4 2 Power Supply Specifications 21 4 3 Failsafe Relay Specifications 21 4 4 Failsafe Relay Isolation 21 4 5 RJ45 Ethernet Port Specifications 22 4 6 Fiber Optic Port Specifications 2...

Page 6: ...roduct contains a laser system and is classified as a CLASS 1 LASER PRODUCT Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiat...

Page 7: ...950G supports the IEEE 1588 v2 Precision Timing Protocol and provides 1 s accuracy for demanding automation applications such as IEC 61850 9 2 process bus and motion control IEC 61850 3 and IEEE 1613...

Page 8: ...EE 1588 v2 Precision Timing Protocol support Wire speed Gigabit throughput with cut through switching to minimize latency Synchronous Ethernet guarantees 1 s accuracy with any network size Connect mul...

Page 9: ...pical HSR Ring Application When the Sending Node communicates the RS950G sends duplicate packets onto the network in opposite directions Using cut through switching packets are moved through the HSR n...

Page 10: ...ical HSR Inter Ring Application Unlike other Ethernet ring protocols HSR is not limited to single ring architecture In Quadbox mode multiple inter ring communications can be set up to increase the sca...

Page 11: ...bility and precision timing are critical in High Availability Networks controlling process automation The RS950G with IEEE 1588 v2 transparent clock is capable of 1 s accuracy Multicast IEEE 1588 v2 t...

Page 12: ...ailability Networks requiring redundant parallel physical and layer 2 hardware use the RS950G and RuggedNet devices in Parallel Redudancy Protocol PRP mode Similar to HSR duplicate packets are generat...

Page 13: ...Power on Alarm LED Red Solid Alarm condition exists Quad Mode Green Solid Unit is in High Availability Seamless Ring HSR Quad Mode with three other RS950G units in an inter ring configuration PRP Gree...

Page 14: ...e top of the unit aligning the holes in the bracket with the threaded holes in the unit Secure the top bracket to the unit with the two Phillips pan head bracket mounting screws removed earlier Repeat...

Page 15: ...S950G Installation Guide Rev 100 2 2 DIN Rail Mounting An optional DIN rail mounting bracket is available for the unit Section 2 2 DIN Rail Mounting provides dimensions and details for standard 1 DIN...

Page 16: ...nd via a braided cable or other appropriate grounding wire Surge Ground is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 4 Chassis Ground must be...

Page 17: ...nding wire Surge Ground is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 3 Chassis Ground must be connected to the protective earth 1 Equipment mu...

Page 18: ...tric Strength Testing 2 4 Console Port Wiring The RS232 port is used for configuring the unit A straight through serial cable with a DB 9 connector is required There is no need to crossover the Transm...

Page 19: ...t 3 1 1 Transient Protection RuggedCom does not recommend the use of copper cabling of any length for critical real time substation automation applications However transient suppression circuitry is p...

Page 20: ...00LX transceiver ports The RS950G supports the use of LC connectors in the SFP ports The Transmit Tx and Receive Rx connections of each port must be properly connected and matched for proper link and...

Page 21: ...Rating Isolation Maximum Power Consumption 12 24 VDC 10 VDC 36 VDC 3 15 T a 1 5 kV DC 24 VDC 18 VDC 36 VDC 3 15 T a 1 5 kV DC 48 VDC 36 VDC 72 VDC 3 15 T a 1 5 kV DC HI 125 250 VDC b HI 110 230 VAC b...

Page 22: ...ance km Power Budget dB 50 125 0 5 FG51 MM LC 62 5 125 850 9 2 5 20 0 0 3 11 FG52 SM LC 9 125 1310 9 5 3 19 3 10 9 5 FG53 SM LC 9 125 1310 7 3 23 3 25 16 FG54 SM LC 9 125 1550 0 5 23 3 70 23 50 125 TB...

Page 23: ...G Installation Guide Rev 100 4 5 Mechanical Specifications Parameter Value Dimensions 18 8 6 6 12 7 cm 7 4 2 6 5 0 inches H W D Weight 1 22 kg 2 7 lbs Enclosure 20 AWG Galvanized Steel Table 4 7 Mecha...

Page 24: ...m for 1 s RuggedCom specified severity levels IEC 61000 4 8 Magnetic Field Enclosure ports 1000 A m for 1s 5 D C Power ports 30 for 0 1s 60 for 0 1s 100 for 0 05s N A IEC 61000 4 29 30 for 1 period 6...

Page 25: ...rts 2 5kV common 1kV diff mode 1MHz Signal ports 5 kV Failsafe Relay D C Power ports 5 kV C37 90 6 H V Impulse A C Power ports 5 kV Signal ports 2kV AC D C Power ports 2kV AC C37 90 6 Dielectric Stren...

Page 26: ...following test procedure No physical damage TS 2 1998 Section 2 para 2 1 10 Mechanical Shock 10g half sine wave for 11msec on all three planes EUT functioned properly following test procedure No phys...

Page 27: ...60950 UL 60950 Approved CE EN 60950 EN 61000 6 2 CE Compliance is claimed via Declaration of Self Conformity Route FCC FCC Part 15 Class A Approved CISPR EN55022 Class A Approved FDA CDRH 21 CFR Chap...

Page 28: ...s product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void For warranty details visit www RuggedCom com or contact your customer...

Reviews: