6. Alarms
ROX™ v2.2 User Guide
93
RuggedBackbone™ RX1500
6.2.1. Administrative Alarm Configuration
Figure 6.9. Admin Alarm Configuration table
The path to the Admin Alarm Configuration table is admin/alarm-config/admin.
Figure 6.10. Admin Alarm Configuration form
The path to the Admin Alarm Configuration form is admin/alarm-config/admin/{alarm id}.
id
Synopsis: integer
This is the ID number of the alarm assigned by the system.
description
Synopsis: A string
The name of the alarm.
severity
Synopsis: string - one of the following keywords { debug, info, notice, warning, error, critical,
alert, emergency }
The severity level can be one of emergency, alert, critical, error, warning, notice, info, and debug.
This cannot be changed for some alarms
admin-enable
If disabled, the alarm is not reported in the active list and does not actuate led/failrelay.
failrelay-enable
If enabled, this alarm will assert the failrelay.
led-enable
If enabled, the main 'Alarm' LED light will be red when this alarm is asserted. If disabled, the main
'Alarm' LED light is not affected by this alarm.