T504 AP Installation Guide, 800-71032-001 Rev D
Installing the T504
Deploying the T504
22
Earth Grounding the T504
The cable strand is usually earth-grounded, and mounting the T504 on the cable strand earth grounds
the T504 chassis as well; if this is the case, skip this procedure and continue with
CAUTION!
Be sure that earth grounding is available and that it meets local and national electrical
codes. For additional lightning protection, use lightning rods and lightning arrestors.
If the cable strand is not earth-grounded, then continue with the following:
1
The color coding of ground wires varies by region. Before completing this step, check your local
wiring standards for guidance.
2
Using the factory-supplied ground screw and washers, use the factory-supplied earth ground
wire with ring terminal to connect a good earth ground to the T504 using the chassis ground
screw shown in
CAUTION!
The T504 includes one 12mm stainless steel M6x1 earth ground screw with split lock
and flat washers. Make sure that any replacement screw is no longer than 12mm. If a screw is longer
than 12mm, it can damage the T504 chassis.
You have earth-grounded the T504. Continue with