![Ruckus Wireless ZoneFlex 7761-CM Installation Manual Download Page 65](http://html1.mh-extra.com/html/ruckus-wireless/zoneflex-7761-cm/zoneflex-7761-cm_installation-manual_1498965065.webp)
59
Resetting the CM Only to Factory Default Settings
Using the Reset Shunt
14
Resetting the CM Only to Factory Default
Settings
CAUTION:
Performing this procedure resets only the CM component to its factory default
settings. If you want to reset both the CM and AP components to factory default settings,
then perform the procedures described in
“Resetting CM and AP to Factory Default
You can use SNMP on either the access point or cable modem to reset the CM to factory
default settings. The procedure is the same, regardless whether you perform this operation
from the AP or CM.
NOTE:
Before starting this procedure, you must first obtain the related MIBs from Ruckus
Wireless. Contact your authorized Ruckus Wireless sales representative or Ruckus Wireless
Support. Visit
http://support.ruckuswireless.com/contacts
for Ruckus
Wireless Support contact information.
1.
Connect the administrative computer to the same network as the CMAP.
2.
Start your MIB browser.
3.
Load the Ruckus Wireless MIBs onto the MIB browser.
4.
In the MIB browser, specify the IP address of the 7761-CM access point or cable
modem. (You can obtain this information from the DHCP server on the network.)
5.
Find the OID
1.3.6.1.4.1.25053.3.1.4.7.3
(ruckusZF7761CMControlLED).
6.
Set the value to
15
(factoryResetCM).
You have completed resetting the cable modem to factory default settings using SNMP.