EN-59
8 | Instruments (Display Modes) | 8.2 | The Program Meter Instrument
EN
SurroundControl 31900/31960 Series
8.2.1.2 | Functions of the Peak Program Meter
The functions of the Program Meter instrument in PPM mode can be selected by clicking the numbered buttons in the Toolbar
or by pressing the corresponding keys.
For digital input signals, the reference point on scales
DIN+5, DIN+10, Nordic, British IIa, British IIb, Zoom20
and Zoom2 corresponds to the set headroom value. Fac-
tory default: –9 dBFS.
• PHold
(Button/key 4)
This function activates or deactivates the PPM’s peak hold
display. The function has no effect on the numerical display.
• SPL
(Button/key 5)
This function activates or deactivates the volume level dis-
plays of the individual channels.
•
Meter In analog/Monitoring
(Button/key 6)
This function changes the source of the
Program Meter
without affecting the monitoring. The
Program Meter
can
either follow the
Monitoring
or use the input selected on
the
Meter Input Routing
menu page. Available selections
for this are
Meter In analog
and
Digital 3
.
• Memory
(Button/Key 1)
Depending on the preset, this function activates the
numerical display of the longterm memory for maximum
level, volume level or digital errors.
• Reset
(Button/key 2)
This function is used to reset the longterm memory, the
peak hold memory and the stored digital errors.
• Gain
(Button/key 3)
This function activates the measurement range expansion
and adapts the peak meter scale accordingly. The additi-
onal gains are applied in accordance with the respective
measuring standards:
Mode/Standard Gain
Digital scales
40 dB
DIN
20
dB
Nordic
40
dB
British IIa + IIb
40 dB
VU
20
dB
Zoom20
20 dB
+24 dBu
20 dB
+20 dBr
20 dB
Summary of Contents for SurroundControl 31960 Series
Page 1: ...SurroundControl 31960 Manual...
Page 2: ...SurroundControl 31960...
Page 3: ...DE SurroundControl 31960 Serie Bedienungsanleitung...
Page 12: ...Inhaltsverzeichnis DE 10 SurroundControl 31960 Serie...
Page 217: ...EN SurroundControl 31960 Series Operating Manual...
Page 226: ...Content EN 10 SurroundControl 31960 Series...
Page 252: ...6 First Use 6 13 Using Loudness Display Options EN 36 SurroundControl 31900 31960 Series...
Page 268: ...7 Control 7 3 External control via GP IO connector EN 52 SurroundControl 31900 31960 Series...