Intercom system numbers are the numbers that appear in the “Icm” column in CStrunk
when you select “Names” or “Setup” from the Intercoms menu.
4. Enter the relay number (2 in this example).
☞
If the relay is in a remote intercom system, you must enter 2 digits by
adding a leading zero if required. If the relay is in the local intercom
system, you do not have to enter a leading zero.
5. Tap the PGM key.
6. Press a talk (or listen) key.
If a talk key is pressed, the name of the relay will appear in the alpha-numeric display above
that talk key (on keypanels so equipped). If a listen key is pressed, the relay name will appear
briefly in the alpha-numeric display below that key, and after a few seconds, the talk key
assignment for that key will reappear. (To check listen key assignments at any time, use the
listen key display request sequence: FUNC__DISPLAY__3.)
☞
If a key will not accept an assignment, the relay that you are trying to assign may have been restricted (not
enabled) by the intercom system configuration software. The intercom system configuration software can also
be used to restrict individual keypanel keys to prevent key assignments.
3.5.2.8
Programming a Stacked Talk Key
A stacked talk key activates two types of communication at once. For example, a stacked talk key could simulta-
neously activate audio output to a transmitter and key the transmitter using a relay. The audio output is called a
level 1 assignment and the relay is called a level 2 assignment. Anything that could be programmed as a normal
talk key assignment may be stacked (except that all-call cannot be assigned to level 2). To program a stacked talk
key:
1. Program level 1 exactly as you would any talk key assignment.
2. Program level 2 like any talk key assignment, except enter 00 before the key sequence.
Example: Assign panel number 45 of the local intercom as the level 1 key assignment and assign relay 5 of the
local intercom as level 2:
24 KP96/KP97 Keypanel Operation Manual, Ver. 8.3G
MULT
FUNC
0
PL
IFB
2
PGM
PREFIX
TYPE
5