The information available for key assign is as follows:
Alphas
Aux Select
CWW
Display
Footswitch
Intercom Mode
Key View
Keypad
LCD Backlight
Local GPIO
Mirror
OMNEO Setup
Page Change
Reset Cfg
RVON Setup
Scrn Saver
Set Address
Snoop Tally
Test Panel
Service Menu, Alphas
The
Alphas
menu is used to select the alpha size (length) and type to be displayed for key assignments.
NOTE:
When a Reset Cfg is performed, the Alpha Size, Poll ID, and Intercom Mode are not reset.
Available options are:
4 Chars
6 Chars
8 Chars
8 Chars (Unicode)
IMPORTANT:
Keypanels on the same AIO-8, or on the same group of eight on an AIO-16, Zeus I/II (but not III), or
ADAM CS must have the same alpha size selected. But each group of eight can support a different
alpha size.
To
set the alpha size
, do the following:
1.
Starting at the Service|Alphas menu, select
4 Chars
,
6 Chars
,
8 Char
, or
8 Chars
(Unicode)
.
2.
Press the
SEL button
.
Cancel and Save and Restart appear in the panel display.
3.
Using the arrow buttons, select
Save and Restart
.
4.
Press the
SEL button
.
The keypanel restarts itself with the new alpha size
.
Summary of Contents for KP-4016
Page 4: ...Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 4 KP Series...
Page 8: ...Bosch Security Systems Inc Technical Manual 8 KP Series Rev 05 F 01U 304 914...
Page 12: ...Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 12 KP Series...
Page 160: ...160 Basic Operation KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Page 292: ...292 KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Page 302: ...302 KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...