28 KP9X Series Keypad Programming
KP-32 User Manual
Bosch Security Systems, Inc.
User Manual
F.01U.193.253
Rev. 16
Display Setup Page Assignments
FUNC DISPLAY E-PNL
Currently, there are four setup pages available for each keypanel. Each setup page defines a set of 16 talk and listen key
assignments. Most RTS keypanels have a maximum of 16 keys, so one setup page is typically assigned to the main keypanel,
and is referred to as the “Main” setup page. Additional setup pages are assigned to any connected expansion panels, and are
referred to as Expansion 1, Expansion 2, etc.). Since the KP-32 requires 2 setup pages, it uses the main page assignments and
also one expansion page (). The EKP-32 uses two additional expansion pages.
When you enter the sequence
FUNC DISPLAY E-PNL
, the
Call waiting
window displays Mn-1 or Mn-2, etc. This indicates
which setup page is currently being used at the “Main” position. After a few moments X1-1, or X1-2, etc displays. This
indicates which setup page is currently being used by expansion 1. Next, if there is an expansion panel connected, X2-1, or
X2-2, etc displays, followed by X3-1 or X3-2. etc to indicate the setup page usage for expansion 2 and expansion 3.
NOTE:
To change the setup page assignments, see “Keypad Programming, Assigning Setup Pages” on page 30.
Test Keys and Displays
FUNC DISPLAY 0
When you enter this sequence, all alpha-numeric displays show a % symbol. Pressing down on any key (except the
Headset /
Vol. Sel
. key) cause
OK
to display. This verifies operation of the key. Tapping up or down on the
Headset / Vol. Sel.
key
causes the display to cycle through the available selections.
If latching is enabled, tapping up or down on any intercom key, or the
Call waiting
key, causes the corresponding red LED to
light. This verifies latching operation and also that the each red LED is OK.
Holding any key in the up or down position causes the corresponding green LED to light. This verifies operation of the green
LEDs.
NOTE:
This sequence is similar to “Service Menu, Test Panel” on page 54, except that the service menu test also lets you
check the operation of the keypad buttons.
Tone Generator Activation (FUNC-DISPLAY-7)
FUNC DISPLAY 7
This sequence activates the keypanel's internal tone generator. You can use the tone generator to check the audio send and
receive paths to and from the matrix. For example, you can assign a talk key on the keypanel to talk to itself. When you
activate the talk key, you should be able to hear the tone from the keypanel speaker or from a headset.
To turn off the tone generator, press the
CLR
key.
NOTE:
The microphone input is turned off when the tone generator is active.
FIGURE 21.
Setup page usage for the KP-32 and EKP-32
Summary of Contents for EKP-32
Page 4: ...Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 iv KP 32 User Manual ...
Page 12: ...Bosch Security Systems Inc User Manual 8 KP 32 User Manual Rev 16 F 01U 193 253 ...
Page 14: ...Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 2 KP 32 User Manual ...
Page 88: ...76 Glossary KP 32 User Manual Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 ...
Page 114: ...102 KP 32 User Manual Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 ...