DKP-4016
DKP-4016 Menu System 221
Bosch Security Systems, Inc.
Technical Manual
F.01U.308.248
Rev. 03
Key Options Menu, Tallies
Tallies
are used to indicate incoming calls with blinking alpha assignments. You can configure tally time as 5, 10, or 15
seconds or set it as indefinite.
If indefinite is selected, when a caller presses and releases the talk key, a tally with a minimum duration appears. If the call is
answered before the minimum duration is met, the tally is cancelled. However, if indefinite is selected and a caller presses and
holds (or latches) the talk key, the tally continues until the caller releases the key. This means the tally continues through the
call if the caller does not release the key.
NOTE:
When DKP-4016/4016W keypanels are connected to legacy intercoms (for example, intercoms that do not
support Enhanced Tallies, the available options for this menu are relevant.
When DKP-4016/4016W keypanels are connected to intercoms that support Enhanced Tallies, the Enhanced
Tallies view allows you to globally configure how the tally behaves. (the options in the Tally menu in the
keypanel are not relevant). For more information, see “Enhanced Tallies” on page 74.
By default, tallies are set to
15 seconds
.
To
set the tally time on an incoming call
, do the following:
1.
Starting at the Key Options|Tallies menu, select
Min Duration
.
2.
Press the
SEL button
.
A Min Duration scroll box appears in the panel display.
3.
Using the up and down arrow buttons, select the
duration
you desire.
To
set the tally time to indefinite on an incoming call
, do the following:
1.
Starting at the Key Options|Tallies menu, select
Indefinite
.
2.
Press the
SEL button
.
Disabled and Enabled appear in the panel display.
3.
Using the up and down arrow buttons, select
Disable
or
Enable
.
Key Options Menu, Turn Off
The
Turn Off
menu item allows the user to quickly turn off all keys, all talk keys, or all listen keys. This menu item can be
used with the programmable UPG keys to create a UPG key which can turn off all keys with one (1) push of a key.
To
turn off keys on the keypanel using the menu
, do the following:
1.
Starting at the Key Options|Turn Off menu, select
All Keys
,
Talk Keys
, or
Listen Keys
.
2.
Press the
SEL button
.
Turn Keys Off? appears in the keypanel panel display.
3.
Press the
SEL button
.
Keys Turned Off appears in the keypanel panel display.
To
configure a UPG to turn off keys
, do the following:
1.
Starting at the Key Options|Turn Off menu, select
All Keys
,
Talk Keys
or
Listen Keys
.
2.
Press the
SEL button
.
Turn Keys Off? appears in the keypanel panel display.
3.
Press the
SEL button
.
Keys Turned Off appears in the keypanel panel display.
4.
On the keypanel, press and hold a
UPG key
until the message Menu position saved appears in the keypanel panel
display.
Keys Turned Off appears in the keypanel panel display once the UPG key is released.
Summary of Contents for DKP-4016
Page 4: ...Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03 4 DKP 4016...
Page 8: ...Bosch Security Systems Inc Technical Manual 8 DKP 4016 Rev 03 F 01U 308 248...
Page 18: ...18 Introduction DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Page 30: ...30 Installation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Page 278: ...278 DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...