Gating
Gating
allows you to minimize or eliminate background noise problems by shutting off an audio source when the sound level
drops below a certain threshold.
Available options for this menu are:
Aux 1 - 6
This feature is only available when the GPI 32 CLD option card is installed.
Headset Mic
Matrix
Panel Mic
Rear Headset Mic
This feature is only available when the GPI 32 CLD option card is installed.
Rear Panel Mic
This feature is only available when the GPI 32 CLD option card is installed.
RVON Ch1
This feature is only available when the RVON-2 option card is installed.
RVON Ch2
This feature is only available when the RVON-2 option card is installed.
The range is for this field is
-17dB
to
18dB
and
Disabled
.
By default, the gating threshold is set to
Disabled
.
NOTE:
0dB
threshold is
12dB
below nominal. Nominal inputs are as follows:
Aux In 1-6
8dBu
Headset Mic
-50dBu
Matrix In
8dBu
Panel Mic
-42.5dBu
RVON Ch1
8dBu
RVON Ch2
8dBu
To
configure gating on the KP 32 CLD keypanel
, do the following:
1.
On the KP 32 CLD keypad, press
MENU
.
The Top Level menu appears
.
2.
Using the 3(
) or 6(
), select
Audio Options
.
3.
Press the
SEL
button.
The Audio Options submenu appears.
4.
Using the 3(
) or 6(
), select
DSP Funcs
.
5.
Press the
SEL
button.
The DSP Funcs menu appears in the display window.
6.
Using the 3(
) or 6(
), select
Gating
.
7.
Press the
SEL
button.
Aux In 1, Aux In 2, Aux In 3, Aux In 4, Aux In 5, Aux In 6, Front Hdst, Front Mic, Matrix In, Rear Hdst, Rear Mic,
RVON Ch1, and RVON Ch2 appear in the display window.
8.
Using the 3(
) or 6(
), select
Aux In 1, Aux In 2, Aux In 3, Aux In 4, Aux In 5, Aux In 6, Front Hdst, Front Mic,
Matrix In, Rear Hdst, Rear Mic, RVON Ch1
, or
RVON Ch2
.
Summary of Contents for DKP 16 CLD
Page 4: ...Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 4 KP32CLD ...
Page 62: ...52 Basic Operation KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 154: ...144 KP 32 CLD Menu System KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 186: ...176 KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 192: ...182 KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 222: ...212 KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 226: ...216 KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 231: ...KP32CLD 221 Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 Notes ...