Configure a RVON card in the Frame using AZedit to contact the RVON-2
To
configure the RVON-2 card
, do the following in AZedit:
1.
From the Status menu in AZedit, select
I/O Cards
.
The I/O Card Status window appears showing the types of installed cards.
2.
Right click an
RVON card
and select
RVON Configuration
.
The RVON Configuration screen appears
.
NOTE:
•
The RVON card you use should be already configured. If it is not configured, refer to the specific
RVON User Manual.
•
Remember, the RVON-2 has only one (1) channel that can be configured as the matrix port. The second
channel is always an AUX port.
3.
From the RVON Channel drop down list, select the
channel
to be used to communicate to the RVON-2 card across
the network.
4.
In the Device IP field, enter the
IP Address
for the RVON-2 card.
5.
From the Device Type drop down list, select
RVON Keypanel
.
6.
From the Device Channel drop down list, select
Channel 1
or
Channel 2
.
There may be two (2) channels listed, but a matrix port connection can only be made through channel 1.
7.
From the CODEC Type drop down list, select the
CODEC type
.
8.
From the Packet Size drop down list, select the
size
of each audio packet.
NOTE:
A CODEC is an algorithm used to compress audio. Codecs dictate the quality of audio you hear and the
network bandwidth used. The packet size determines how much audio data is carried across the network
in each transmitted packet. The CODEC type and packet size chosen require different amounts of
bandwidth from the network. As with the CODEC type, the packet size you choose for the audio
transfer affects the audio you hear and the bandwidth you use over the network. The larger the audio
packet you choose to use, the lower the bandwidth used. However, the larger packet size can result in a
higher delay and longer gaps if the packet is lost. On the other hand, smaller packet sizes result in larger
bandwidth use, but lower delays and smaller gaps if the packet is lost. The Intercom System Engineer
and the Network Designer may want to work together in choosing the CODEC type and packet size
suitable for the size of the network, so degradation of network resources does not occur.
Summary of Contents for DKP 16 CLD
Page 4: ...Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 4 KP32CLD ...
Page 62: ...52 Basic Operation KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 154: ...144 KP 32 CLD Menu System KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 186: ...176 KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 192: ...182 KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 222: ...212 KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 226: ...216 KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 231: ...KP32CLD 221 Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 Notes ...