background image

RT-2M (90007891000) Quick Start Guide

NOTE:

See the entire system diagram on reverse side.

RS-232 Cable Pinout

Step 1. 

Cable the Trunk Supervisor/TrunkEdit PC to the 

RT-2M.

NOTE:

In Trunk Supervisor, you must designate 

the intercom and port number the RT-2M  
sends the test signal over.

To 

cable the Trunk Supervisor/TrunkEdit PC to the 

RT-2M

, do the following:

1.

Using the included cable, connect a 

COM port

  on 

the Trunk Supervisor computer to the 

RS-232 

Interface

 

connector

 on the rear panel of the RT-2M.

Step 2. 

Cable the RT-2M to the Frame.

To 

cable the RT-2M to the Frame

, do the following:

1.

Using the appropriate connector defined below, connect the 

RT-2M 

to the Frame:

2.

Connect the

 other end of the connector

 to the trunking 

connection port as defined in the Trunk Supervisor software. 

CONNECTOR

CONNECTION

RJ-12

Plug 

pins 2

 and 

5

 into the Ch 1 input connector terminals.

Plug 

pins 3 

and 

4

 into the Ch 1 output connector terminals.

DB-9

Plug

 pins 7

 and 

into the Ch 1 input connector terminals

Plug 

pins 4

 and

 5

 into the Ch 1output connector terminals.

INCLUDED PARTS:

RT-2M Unit

DB-9 Cable

LIT000306000 Rev. A

11/2008