Printer Failure Alarm
System relays RL3 - RL8 can be software configured to operate in the event of a
printer failure alarm being received by the 9000TS System.
Time Sync. Failure
System relays RL3 - RL8 can be software configured to operate in the event of a time
sync. error signal being generated by the 9000TS System
Buffer Overload Alarm
System relays RL3 - RL8 can be software configured to operate in the event of a
buffer overload signal being generated by the 9000TS System
Watchdog Relay:- WD
RL9 is factory set as a watchdog relay
The relay is normally de-energised and will energise if the system detects a fault. The
relay will automatically reset when the fault condition has been removed. The coil state
can be changed from normally DE-EN to normally EN using Link LK6 and the contact
state can be set to N/O or N/C using Link LK8 as required.