ECAN1000 User’s Manual
27
BDM-610020026 rev B
Chapter 6
ECAN1000HR
S
PECIFICATIONS
Host Interface
I/O mapped device, occupies 3 bytes
Jumper-selectable base address
8-bit data bus, 16-bit AT bus connector
Jumper selectable XT and AT interrupts
CAN Interfaces
Galvanically isolated transceiver 1 Mb/s data rate
Timing parameters and speed of bus programmable
Balanced CAN bus Choke
Jumper selectable 120 Ohm termination resistors
Transceiver type: Philips 82C251
0.8W 5V isolated output power for other field devices
Connectors
Galvanically isolated CAN bus 90 degree 10-pin header
Host bus XT/AT PC/104 bus
Electrical
Operating temperature range -40 to +85 C
Supply voltage +5V, +-8%
Power consumption 1,0W typical
CE
The ECAN1000HR is CE certified in the IDAN Enclosure System.
Please consult the factory for more information on the system.