Metering
Metering
In the METER SETUP popup you can change the level detection
point of the meter, and make peak hold settings.
fig.ScrMeterSetupGuide.eps
1.
CH METERING POINT selection buttons
Use these to select the level detection point for the CH meters.
2.
AUX/MAIN/MATRIX METERING POINT selection buttons
Use these to select the level detection point for the AUX/
MAIN/MATRIX meters.
If you select PRE EQ, the level at the pre-fader position will be
shown for MATRIX channels.
3.
OVER Lev knob
This adjusts the level at which the OVER indication of the meter
will light, in a range of -18 dB–0 dB.
4.
PEAK HOLD button
This turns the meter’s peak hold function on/off.
5.
HOLD TIME knob
This sets the duration that the meter’s peak hold or OVER
indication will stay lit, in a range of 1 sec–4 sec or CONTINUE.
Meter peak hold is enabled only when the PEAK HOLD button
is on.
If CONTINUE is selected, the indication will remain until you
execute the PEAK CLEAR operation (by pressing a function
button) in the METER screen, etc.
In the METER SETUP popup, the function buttons perform the
following operations.
1.
Access the METER screen.
fig.ScrMeter.eps
2.
Press [F4 (METER SETUP)] to access the METER SETUP
popup.
fig.ScrMeterSetup.eps
Editing the meter settings
METER SETUP popup
[F8 (CLOSE)]
Closes the popup.
1
2
3
5
4
Accessing the METER SETUP popup
The METERING POINT setting you make in the METER SETUP
popup will apply to the top panel meters, the meters in the
METER screen, the channel meters in the CHANNEL DISPLAY
screen, the MONITOR screen, and the meters in the
TALKBACK/OSC screen.