102
Dynamics
Dynamics
fig.ScrCompOverviewGuide.eps
1.
Overview
This shows the overall compressor status for CH1–CH48.
fig.ScrCompOverviewGuide2.eps
a. Channel number
b. ON switch
Turns the compressor on/off.
c. Compressor graph
Shows the approximate response of the compressor.
d. GR meter
Shows the amount of gain reduction for the compressor.
e. THR knob
Adjusts the threshold level of the compressor in a range of -40.0
dB–0.0 dB.
2.
COMP REMAIN indication
Indicates the remaining number of compressor units that can be
turned on. If this indicates 0, no further units can be turned on.
Stereo-linked channels will use two compressor units. This
means that if the COMP REMAIN indication is 1, you won’t be
able to turn on the compressor for a stereo-linked channel. If
you enable stereo-linking for a channel when the COMP
REMAIN indication is 0, and this would cause the number of
compressor units to exceed 24, the compressor for that channel
will be turned off.
In the COMPRESSOR OVERVIEW popup, the function buttons
perform the following operations.
Accessing the COMPRESSOR
OVERVIEW popup
1.
Access the COMPRESSOR popup.
fig.PopComp.eps
2.
Press [F1 (OVERVIEW)] to access the COMPRESSOR
OVERVIEW popup.
fig.ScrCompOverview.eps
COMPRESSOR OVERVIEW popup
1
2
a
b
c
d
e
[F8 (CLOSE)]
Closes the popup.
If you attempt to turn on more than twenty-four compressor
units, the following warning message will appear, and no
further units can be turned on.
fig.ScrCompOvMsg.eps
M-400_v15_e.book 102 ページ 2008年6月20日 金曜日 午後4時5分