RSIalarm videofied SE600 Installation Manuallines Download Page 1

www.videofied.com

Product Summary

The Interior Siren Model SE 600 is a wireless siren 
designed for use in RSIalarm™ security systems. 
The siren includes the following features:

 Totally wireless, battery operated

 Dual tamper function provides detection for both wall 

  and cover tamper.

 Transmits check-in/status signal every 8 minutes

Installation Guidelines

For easier installation, programming and RF testing 
should be done to check for good communication between 
the control panel and all system devices before mounting 
system devices. Install the siren and other system devices 
in the following order:

>

  Programming/RF Testing—program detector 

  and all other devices into the control panel and test 
  RF communication from each intended device location 
  to the control panel.

>

  Mounting—mount detector at the tested location.

Programming/RF Testing

The following provides summarized steps for device 
programming and testing. For complete details, refer 
to the control panel installation manual.

1

 Remove bottom screws,

 

separate cover from siren

 

and install batteries.

2

 Put control panel 

 into 

 

programming/

 confi guration mode.

3

  Using a programmed

 alphanumeric 

keypad, 

 proceed 

through 

menus

 

until the display shows 

 

ADD A NEW DEVICE.

4

 Press 

Yes.

 The display 

 

shows PRESS PROGRAM 

 

BUTTON OF DEVICE. 

5

  Press and release 

 

program button on siren 

 

using a paper clip end.

 

The siren LED fl ashes.

 

Wait for keypad display 

 

to show SIREN (1 - 25)  

 

 RECORDED.

6

 Press 

Yes.

 The display shows RADIO RANGE TEST? 

 Press 

Yes

 again. The siren LED starts fl ashing and 

 

keypad display shows TEST IN PROGRESS. 

7

  Take siren to its intended mounting location and 

 

make sure LED fl ashes continuously, indicating good 

 

communication with control panel.

8

 Press 

Yes

 to end radio range test, then press 

Esc/No.

9

  The display shows RECORDING A NEW DEVICE?

 

Repeat steps 4 - 8 for remaining sirens.

10

 When fi nished, exit from confi guration mode.