Quick Guide
RSSA3000X
Spectrum Analyzer
Page 1: ...Quick Guide RSSA3000X Spectrum Analyzer...
Page 2: ...2...
Page 3: ...an reach the product or else the operator might be exposed to danger of electrical shock Electrostatic Prevention Operate the instrument in an electrostatic discharge protective area environment to av...
Page 4: ...ct injuries or hazards that may happen WARNING indicates potential injuries or hazards that may happen CAUTION Indicates potential damages to the instrument or other property that may happen Symbols o...
Page 5: ...according to its operating conditions 1 Disconnect the instrument from all power sources and then clean it with a soft cloth 2 Clean the loose dust on the outside of the instrument with a soft cloth...
Page 6: ...nstrument has passed both electrical and mechanical tests 2 Inspect the instrument If the instrument is found to be damaged defective or fails in electrical or mechanical tests please contact your sal...
Page 7: ...7 Appearance and Dimension Figure 1 Front View Figure 2 Top View...
Page 8: ...ing Legs Adjust the supporting legs properly to use them as stands to tilt the Spectrum Analyzer upwards for stable placement as well as easier operation and observation of the instrument Before adjus...
Page 9: ...to AC Power Supply The Spectrum Analyzer accept 100 240V 50 60 440Hz AC power supply Please use the power cord provided as accessories to connect the instrument to the power source as shown in the fig...
Page 10: ...interface clear display with plenty of RF measurement functions The product can be used for research and development education production maintenance and other relevant applications The Front Panel 1...
Page 11: ...he characteristics of the signal BW Used to adjust the RBW VBW VBW RBW Rate Average Type Logpower Power Voltage Trace Selects Trace Trace setup Trace math Sweep Selects the Sweep time Sweep Rule Sweep...
Page 12: ...rameters Details of Channel Power ACPR Occupied BW T Power System Selects the Language Power on Preset Interface Calibration system information Data Time Self Test Mode Selects the Spec Analyzer EMI R...
Page 13: ...13 The Rear Panel 1 1 Handle 2 USB Device 3 LANInterface 4 10MHz REFInput 5 10MHz REF Output 6 TriggerIn 7 SafetyLockHole 8 AC PowerSocket...
Page 14: ...t the input signal to the RF input port does not contain more than 50 Volts DC The AC radio frequency input signal component should not exceed a maximum continuous power level of 30dBm 2 TG OUTPUT WAR...
Page 15: ...15 1 3 4 Parameters setting area 2 Menu setting area 5 Active parameter 6 Display area 1 5 2 6 4 3 User Graphical Interface...
Page 16: ...numbers through System Information For more information of this product please refer to the following manuals provided in the CD in the accessories Spectrum Analyzer User Manual provides detailed int...